WIL-10187-E-05
16
P8 Clamped Plastic
Step 4
Step 5
Step 6
Remove the discharge valve ball, valve
seat and valve seat O-ring and inspect for
signs of wear and replace, if necessary.
Remove the two small clamp bands which
fasten the intake manifold to the liquid
chambers.
NOTE:
Inverting the pump will facilitate
removal of inlet manifold.
Lift liquid chambers and center section
from intake manifold to expose intake
valve balls and seats. Inspect ball cage
area of liquid chamber for excessive wear
or damage.
Step 7
Step 8
Step 9
Remove valve seats and valve balls for
inspection. Replace if necessary.
Remove small manifold clamp bands to
inspect manifold O-rings.
Remove one set of large clamp bands
which secure one liquid chamber to the
center section.
DISASSEMBLY / REASSEMBLY