WIL-10187-E-05
20
P8 Clamped Plastic
Step 9
Step 10
With O-ring pick, gently remove the O-ring
from the opposite side of the notched end of
the spool. Gently remove the pilot spool
from sleeve and inspect for nicks or gouges
and other signs of wear. Replace pilot
sleeve assembly or outer sleeve O-rings, if
necessary. During re-assembly never insert
the pilot spool into the sleeve with the
“notched end” first, this end incorporates the
urethane O-ring and will be damaged as it
slides over the ports cut in the sleeve.
NOTE:
Seals should not be removed from
assembly. Seals are not sold separately.
Check center block Glyd™ rings for signs of
wear. If necessary, remove Glyd™ rings with
O-ring pick and replace.
NOTE:
Threaded sleeves are removable
and can be replaced if necessary. Sleeves
can be press-fit by hand.
DISASSEMBLY / REASSEMBLY