Wilden pumps are designed to meet the performance requirements of 

even the most demanding pumping applications. They have been 
designed and manufactured to the highest standards and are 

available in a variety of liquid path materials to meet your chemical 
resistance needs. Refer to “Performance” for an in-depth analysis of 

the performance characteristics of your pump. Wilden offers the 
widest variety of elastomer options in the industry to satisfy 

temperature, chemical compatibility, abrasion resistance and flex 
concerns. 
 

The suction pipe size should be at least equal to or larger than the 
diameter size of the suction inlet on your Wilden pump. The suction 

hose must be a non-collapsible, reinforced type because these 
pumps are capable of pulling a high vacuum. Discharge piping should 

also be equal to or larger than the diameter of the pump discharge, 
which will help reduce friction losses. 

 

CAUTION:

 All fittings and connections must be airtight. 

Otherwise, pump suction capability will be reduced or lost. 

 
Months of careful planning, study and selection efforts can result in 

unsatisfactory pump performance if installation details are left to 
chance. You can avoid premature failure and long-term dissatisfaction 

by exercising reasonable care throughout the installation process. 
 

Location 

Noise, safety and other logistical factors usually dictate where 

equipment will be situated on the production floor. Multiple 
installations with conflicting requirements can result in congestion of 

utility areas, leaving few choices for additional pumps. 
Within the framework of these and other existing conditions, locate 
every pump in such a way that the following six key factors are 
balanced against each other to maximum advantage: 

 

Access:

 First, the location should be accessible. If it’s easy to 

reach the pump, maintenance personnel will be able to perform 
routine inspections and adjustments more easily. If major 

repairs become necessary, ease of access can play a key role 
in speeding the repair process and reducing total downtime. 

 

Air Supply:

 Every pump location should have an air line large 

enough to supply the volume of air necessary to achieve the 

desired pumping rate. For best results, the pumps should use a 
5

μ

 (micron) air filter, needle valve and regulator. The use of an 

air filter before the pump will ensure that the majority of any 
pipeline contaminants will be eliminated. 

 

Solenoid Operation:

 When operation is controlled by a 

solenoid valve in the air line, three-way valves should be used. 

This valve allows trapped air between the valve and the pump 
to bleed off, which improves pump performance. You can 

estimate pumping volume by counting the number of strokes 
per minute, and then multiplying that figure by the displacement 

per stroke. 

 

Muffler:

 Using the standard Wilden muffler, sound levels are 

reduced below OSHA specifications. You can use other mufflers 
to reduce sound levels farther, but they usually reduce pump 

performance. 

 

Elevation:

 Selecting a site that is well within the pump’s 

dynamic lift capability will assure that loss-of-prime issues will 

be eliminated. In addition, pump efficiency can be adversely 

affected if proper attention is not given to site location. 

 

Piping:

 Final determination of the pump site should not be 

made until the piping challenges of each possible location have 

been evaluated. The impact of current and future installations 
should be considered ahead of time to make sure that 
inadvertent restrictions are not created for any remaining sites. 

The best choice possible will be a site involving the shortest and 
straightest hook-up of suction and discharge piping. Unnecessary 
elbows, bends and fittings should be avoided. Pipe sizes should  

be selected to keep friction losses within practical limits. All piping 
should be supported independently of the pump. In addition,  

the piping should be aligned to avoid placing stress on the  
pump fittings. 

 
Flexible hose can be installed to aid in absorbing the forces created 

by the natural reciprocating action of the pump. If the pump is to be 
bolted down to a solid location, a mounting pad placed between the 
pump and the foundation will assist in minimizing pump vibration. 

Flexible connections between the pump and rigid piping will also 
assist in minimizing pump vibration. If quick-closing valves are 

installed at any point in the discharge system, or if pulsation within a 
system becomes a problem, a surge suppressor (SD Equalizer) 

should be installed to protect the pump, piping and gauges from 
surges and water hammer. 

 
If the pump is to be used in a self-priming application, make sure that 
all connections are airtight and that the suction lift is within the 

model’s ability. 

 

NOTE:

 Materials of construction and elastomer material 

have an effect on suction lift parameters. Please refer to 

“Performance” for specifics. 

 
When pumps are installed in applications involving flooded suction or 

suction head pressures, a gate valve should be installed in the 
suction line to permit closing of the line for pump service. 

 
Pumps in service with a positive suction head are most efficient when 

inlet pressure is limited to 0.5–0.7 bar (7–10 psig). Premature 
diaphragm failure may occur if positive suction is 0.7 bar (10 psig) 

and higher. 
 

 

CAUTION:

 All Wilden pumps are capable of passing solids. 

Use a strainer on the pump intake to ensure that the pump's 

rated solids capacity is not exceeded. 
 

CAUTION:

 Do not exceed 8.6 bar (125 psig) air  

supply pressure. 

 

CAUTION:

 Pro-Flo

®

 pumps do not have single-point exhaust 

option and are not submersible. 
 

 
 
 

 

 

SUGGESTED INSTALLATION, OPERATION, MAINTENANCE  

AND TROUBLESHOOTING 

Содержание PRO-FLO P8

Страница 1: ...WIL 10187 E 05 Where InnovationFlows EOM ENGINEERING OPERATION MAINTENANCE MANUAL P8 Clamped Plastic Pump...

Страница 2: ...alifornia LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are regi...

Страница 3: ...ic TPE Fitted 8 P8 Plastic Reduced Stroke PTFE Fitted 9 P8 Plastic Full Stroke PTFE Fitted 9 P8 Plastic Ultra Flex Fitted 10 Suction Lift Capability 11 SECTION 6 Suggested Installation Operation Maint...

Страница 4: ...the pump s rated solids capacity is not exceeded CAUTION Do not exceed 8 6 bar 125 psig air supply pressure CAUTION The process fluid and cleaning fluids must be chemically compatible with all wetted...

Страница 5: ...E BLACK DOTS VALVE SEATS K PVDF P POLYPROPYLENE O RINGS BN BUNA N RED DOT PU POLYURETHANE BROWN TV PTFE ENCAP FKM WF WIL FLEX SANTOPRENE SPECIALTY CODES 0100 Wil Gard II 110V 0102 Wil Gard II sensor w...

Страница 6: ...d manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump dis...

Страница 7: ...M METRIC mm STANDARD inch A 490 19 3 B 76 3 0 C 414 16 3 D 693 27 3 E 770 30 3 F 89 3 5 G 417 16 4 H 333 13 1 J 381 15 0 K 307 12 1 L 227 8 9 M 254 10 0 N 15 0 6 METRIC mm STANDARD inch P 122 DIA 4 8...

Страница 8: ...all in the center of the pump s performance curve Caution Do not exceed 8 6 bar 125 psig air supply pressure P8 PLASTIC TPE FITTED Ship Weights Polypropylene 34 kg 75 lb PVDF 43 kg 95 lb Air Inlet 13...

Страница 9: ...rs will fall in the center of the pump s performance curve Caution Do not exceed 8 6 bar 125 psig air supply pressure P8 PLASTIC FULL STROKE PTFE FITTED Ship Weights Polypropylene 34 kg 75 lb PVDF 43...

Страница 10: ...stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 1 bar 30 psig head pressure Example To pump 257 lpm 68 gpm against a discharge pressure head of 2 0 bar 30 psig requires 4 1 ba...

Страница 11: ...1 000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pumpi...

Страница 12: ...strokes per minute and then multiplying that figure by the displacement per stroke Muffler Using the standard Wilden muffler sound levels are reduced below OSHA specifications You can use other muffle...

Страница 13: ...d to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump This action increases friction loss whic...

Страница 14: ...e unable to shift Pump runs but little or no product flows 1 Check for pump cavitation Slow pump speed down to allow thick material to flow into liquid chambers 2 Verify that vacuum required to lift l...

Страница 15: ...model may vary from the configuration shown however pump disassembly procedure will be the same NOTE The model used for these instructions incorporates rubber diaphragms balls and seats Models with P...

Страница 16: ...pump will facilitate removal of inlet manifold Lift liquid chambers and center section from intake manifold to expose intake valve balls and seats Inspect ball cage area of liquid chamber for excessi...

Страница 17: ...the shaft and the entire assembly can be removed from the center section Figure 12 2 The outer piston diaphragm and inner piston separate from the shaft which remains connected to the opposite side d...

Страница 18: ...uired 3 16 Hex Head Wrench 1 4 Hex Head Wrench Snap Ring Pliers O Ring Pick CAUTION Before attempting any maintenance or repair disconnect the compressed air line to the pump and allow all air pressur...

Страница 19: ...center section with snap ring pliers NOTE Seals should not be removed from assembly Seals are not sold separately Remove pilot spool retaining snap ring on both sides of center section with snap ring...

Страница 20: ...ry During re assembly never insert the pilot spool into the sleeve with the notched end first this end incorporates the urethane O ring and will be damaged as it slides over the ports cut in the sleev...

Страница 21: ...no damage is done to new shaft seals A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to locate gaskets during assembly Make sure that the ex...

Страница 22: ...ith the seal clamped in the pliers insert the seal into the busing bore and position the bottom of the seal into the correct groove When the bottom of the seal is seated in the groove release the clam...

Страница 23: ...dhesive covering from the back of the PTFE tape Ensure that the adhesive strip remains attached to the PTFE tape Starting at any point place the PTFE tape in the center of the diaphragm bead groove on...

Страница 24: ...WIL 10187 E 05 24 P8 Clamped Plastic SECTION 8 P8 FULL STROKE DIAPHRAGM FITTED EXPLODED VIEW AND PARTS LIST ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS...

Страница 25: ...Diaphragm 2 22 Outer Piston 2 08 4550 21 500 08 4550 21 500 23 Manifold Tee Section 2 08 5160 20 08 5160 20 24 Small Clamp Band Assy 4 08 7100 03 500 08 7100 05 500 25 Small HHC Screw 5 16 18 x 2 8 0...

Страница 26: ...WIL 10187 E 05 26 P8 Clamped Plastic P8 PLASTIC REDUCED STROKE EXPLODED VIEW AND PARTS LIST ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS...

Страница 27: ...0 08 19 Retaining Ring 2 04 3890 03 04 3890 03 20 Inner Piston 2 08 3750 01 08 3750 01 Inner Piston Ultra Flex 2 08 3761 01 08 3761 01 21 Diaphragm Back up 2 22 Diaphragm 2 23 Outer Piston 2 08 4600 2...

Страница 28: ...A EPDM 08 1010 54 08 1020 54 N A N A 08 1080 54 N A N A FKM 08 1010 53 08 1020 53 N A N A 08 1080 53 N A Saniflex 08 1010 56 N A N A N A 08 1080 56 08 1060 56 08 1065 56 Non Food Grade Saniflex 08 10...

Страница 29: ...WIL 10187 E 05 29 P8 Clamped Plastic NOTES...

Страница 30: ...WIL 10187 E 05 30 P8 Clamped Plastic NOTES...

Страница 31: ...WIL 10187 E 05 31 P8 Clamped Plastic NOTES...

Страница 32: ...USA P 1 909 422 1730 psgdover com Copyright 2021 PSG a Dover Company PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non co...

Отзывы: