26
WIKA operating instructions SF
6
gas filling cart, model GFU08
14033074.01 11/2018 EN/DE/FR/ES
EN
7.1.3 Automatic zero setting on start
If, during the start, a weight of ± 10 % of the nominal load/weighing capacity is
determined, an automatic zero setting is carried out. If the weight lies outside of this
range, the display on the display unit shows the current weight after a few moments.
7.1.4 Keylock
In order to prevent unwanted entries, the buttons of the display unit can be locked. The
settings for the keylock are made in SETUP.
Automatic keylock
The keypad will be locked after 15 seconds of inactivity in the weighing status (the
display indicates “
LoC.key
”).
Functions with keylock:
■
Switch the display unit off by pressing the C button for 10 seconds. Switches the
display unit back on.
■
Unlocking the keypad: Press the ZERO and ENTER/PRINT buttons one after the
other. (Display shows the message “
unl.key
”). By pressing any other button, the
display shows the message “
Press Zero to unlock
”. By pressing the ZERO
button, the display shows the message “
now Press Print to unlock
”.
Keylock via optional input
The keypad will be locked on closing the input and only unlocked again after opening it.
The display shows no message on locking/unlocking. If a button is pressed, the display
shows the message “
LoCkin
”.
7.2 Switching the display unit on
To switch the display unit on, press the C button until the display unit switches on.
Release the button.
Indication on the display after switching on:
Step
Display
Description
1
HH.YY
Indicates the installed software version.
2
Indicates all segments and symbols in the display.
3
NAH HHH.HHH
Weighing capacity of channel 1.
or
Naster
by selecting the function range
“
Nastr
”
.
or
ripE
by selecting the function range
“
rEpE
”.
4
bt HHH
Indicates the charge status of the battery -
“
H
”
corresponds to
a number from 0 to 100.
5
Display of weighing capacity and scale divisions.
7. Display unit