30
WIKA operating instructions, models F2301, F23C1, F23S1, F2303, F2304
ADPR1X914096.01 06/2020 EN/DE
EN
1) The force transducers with ignition protection type “ib” should only be powered using galvanically isolated repeater power supplies.
2) Relative linearity error is specified in acc. with Directive VDI/VDE/DKD 2638 Chap. 3.2.6.
3) Other signal jumps are realisable upon request.
9. Specifications
Model
F23C1
ATEX/IECEx EX ib
1)
F2301
Signal jump
Supply voltage
DC 10 ... 30 V for voltage
output
DC 10 … 30 V for current
output
DC 14 ... 30 V for voltage
output
Load
≤ (UB – 10 V)/0.024 A for current output
> 10 kΩ for voltage output
Ingress protection
(per IEC/EN 60529)
IP67
Wiring protection
Reverse polarity, overvoltage and short-circuit resistance
Vibration resistance
20 g, 100 h, 50 ... 150 Hz per DIN EN 60068-2-6
Interference emission
DIN EN 55011
Immunity
In accordance with DIN EN 61326-1/DIN EN 61326-2-3
(optional EMC-strengthened versions)
Options
Certificates, strength verifications, 3D-/CAD files (STEP,
IGES) on request