32
WIKA operating instructions, models F2301, F23C1, F23S1, F2303, F2304
ADPR1X914096.01 06/2020 EN/DE
EN
9. Specifications
Model
F2304
Rated force F
nom
kN
1, 2.5, 7.5, 10, 20, 25
Relative linearity error d
lin 2)
±0.5 % F
nom
Relative reversibility error
< 0.1 % F
nom
Relative creep, 30 min. at F
nom
0.1 % F
nom
Temperature effect on
characteristic value TK
c
0.4 % F
nom
/10 K
zero signal TK
0
0.4 % F
nom
/10 K
Limit force F
L
150 % F
nom
Breaking force F
B
300 % F
nom
Permissible vibration loading F
rb
±50 % F
nom
(in accordance with DIN 50100)
Rated displacement (typical) s
nom
< 0.1 mm
Material of the measuring body
Corrosion-resistant stainless steel, ultrasound-
tested 3.1 material (optionally 3.2)
Rated temperature range B
T, nom
-20 … +80 °C
Service temperature range B
T, G
-30 … +80 °C
Storage temperature range B
T, S
-40 … +85 °C
Electrical connection
Circular connector M12 x 1, 4-pin
Output signal
(Rated characteristic value) C
nom
4 … 20 mA, 2-wire
Current/power consumption
4 … 20 mA 2-wire, 4 … 20 mA 3-wire, DC 0 … 10
V 3-wire (Optional redundant signal), CANopen
®
protocol in accordance with CiA 301, device pro-
file 404, communication services LSS (CiA 305),
configuration of the instrument address and baud
rate Sync/Async, Node/Lifeguarding, heartbeat;
zero and span ±10 % adjustable via entries in the
object directory
3)
Power supply
DC 10 ... 30 V
for current output
Load
≤ (UB –
10 V)/0.024 A
for current output
Ingress protection (per EN/IEC 60529)
IP67
Vibration resistance
(to DIN EN 60068-2-6)
20 g, 100 h, 50 ... 150 Hz
Wiring protection
Reverse polarity, overvoltage and short-circuit resis-
tance
Interference emission
DIN EN 55011