27
WIKA operating instructions, models F2301, F23C1, F23S1, F2303, F2304
ADPR1X914096.01 06/2020 EN/DE
EN
Model
F2301
F23S1
Rated force F
nom
kN
1, 2, 3, 5, 10, 20, 30, 50, 100,
200, 300, 500
3, 5, 10, 20, 30, 50, 100
Relative linearity error d
lin 1)
±0.5 % F
nom
Relative reversibility error
< 0.1 % F
nom
Relative creep, 30 min. at F
nom
0.1 % F
nom
Temperature effect on
characteristic value TK
c
0.4 % F
nom
/10 K
zero signal TK
0
0.4 % F
nom
/10 K
Limit force F
L
150 % F
nom
Breaking force F
B
300 % F
nom
Permissible vibration loading F
rb
±50 % F
nom
(in accordance with DIN 50100)
Rated displacement (typ.) s
nom
<10 kN
< 0.02 mm
<100 kN
< 0.2 mm
Material of the measuring body
Corrosion-resistant stainless steel, ultrasound-tested
3.1 material (optionally 3.2)
Rated temperature range B
T, nom
-20 … +80 °C
Service temperature range B
T, G
-30 … +80 °C
Storage temperature range B
T, S
-40 … +85 °C
Electrical connection
Circular connector M12 x 1,
4-pin / CANopen
®
5-pin
2-connector version
M12 x 1, 4-pin
Output signal
(Rated characteristic value) C
nom
4 … 20 mA, 2-wire
4 … 20 mA, 3-wire or
DC 0 … 10 V, 3-wire
(Optional redundant signal)
CANopen
®
protocol in
accordance with CiA 301,
device profile 404, communi
-
cation services LSS (CiA 305),
configuration of the instrument
address and baud rate Sync/
Async, Node/Lifeguarding,
heartbeat; zero and span
±10 % adjustable via entries in
the object directory
2)
Redundant, opposing,
4 … 20 mA /
20 … 4 mA, version in
acc. with requirements
for functional safety per
Machinery Directive
2006/42/EC
9. Specifications
9. Specifications