Installation, operating and maintenance manual
UNIGAS 300
DDG6004MHGB/08-2017/Rev.A2 Software version from M 1.3.40 and D 2.3.37
26
Status register 1;
calibration relevant alarms
St :
1
1
1
2
1
3
1
4
2
1
2
2
2
3
2
4
3
1
3
2
3
3
3
4
Presentation
menu 8.1
Presentation
menu 4, 5, 6
Description
CRC error
interface
1
1
8, 9, A, B,
C, D, E, F
E F CRC error occurred in program memory of the processor of
the top PCB. The memory is checked once per hour
Watchdog
interface
4, 5, 6, 7,
C, D, E, F
E E Watchdog of the program of the processor of the top PCB has
been activated
CRC error
conversion
2, 3, 6, 7,
A, B, E, F
E D CRC error occurred in program memory of the processor of
the bottom PCB. The memory is checked once per hour
Watchdog
conversion
1, 3, 5, 7,
9, B, D, F
E C Watchdog of the program of the processor of the bottom PCB
has been activated
Reset
1
2
8, 9, A, B,
C, D, E, F
E B Software has been rebooted
External power
4, 5, 6, 7,
C, D, E, F
C A External power supply present
Alarm
ENCODER
2, 3, 6, 7,
A, B, E, F
C 9 Readout values from encoder counter are unusable (BCC
error) or a encoder reading is lower than counter reading Vm1
or Vm2. Vm1 or Vm1 will not be modified
NAMUR open
circuit
1, 3, 5, 7,
9, B, D, F
C 8 NAMUR input has been interrupted. The current is lower than
1 mA.
NAMUR short-
circuit
1
3
8, 9, A, B,
C, D, E, F
C 7 NAMUR input has a current greater than 8 mA, NAMUR input
is switched off.
Counters set
4, 5, 6, 7,
C, D, E, F
E 6 A counter reading has been set
Alarm switch
program
2, 3, 6, 7,
A, B, E, F
C 5 Calibration lock opened because calibration switch was
operated
Alarm open
casing
1, 3, 5, 7,
9, B, D, F
C 4 Housing is open
Alarm
temperature
1
4
8, 9, A, B,
C, D, E, F
C 3 Measured value is not between tmin and tmax or
measurement was not possible
Alarm pressure
4, 5, 6, 7,
C, D, E, F
C 2 Measured value is not between pmin and pmax or
measurement was not possible
Error Z of Zb
2, 3, 6, 7,
A, B, E, F
C 1 Error on measuring Z or Zb
Low battery
1, 3, 5, 7,
9, B, D, F
C 0 Battery voltage too low (<2.8 V) or Ah_used > Ah_new
State is ended when menu action exchange battery has been
carried out and the battery voltage is at least 3.3 V
C= condition and E= event