8 Replacing the battery
Batteries must only be replaced by original batteries of type G8610070000 or G8610080000 supplied
by Wigersma & Sikkema. It is permitted to replace the battery in a potentially explosive atmosphere.
Put UNIGAS 300 into sleep mode through menu item 10 prior to replacing the battery. UNIGAS 300
can remain operational in sleep mode for about 17 s without battery (for safety reasons the display will indicate
10 s). During sleep mode, UNIGAS 300 will not carry out any conversion. The clock does keep running. After
sleep mode UNIGAS 300 will activate itself and all functions will become active again.
If replacing the battery takes longer than this sleep mode period, UNIGAS 300 will shut down. The moment
UNIGAS 300 gets powered again, UNIGAS 300 will start up with the most recent backup data. UNIGAS 300
makes a backup every 5-min interval, so the information will not be older than 5 min. The power failure will be
logged in status register 1 and the clock will have to be set again.
Data for battery type G8610070000
•
lithium-Thionyl chloride:
D cell
•
nominal voltage:
3.6 V
•
nominal capacity:
18.5 Ah
•
initial capacity to be entered into UNIGAS 300:
12 Ah (applicable in Western Europe)
Data for battery type G8610080000
•
lithium-Thionyl chloride:
DD cell
•
nominal voltage:
3.6 V
•
nominal capacity:
35 Ah
•
initial capacity to be entered into UNIGAS 300:
21 Ah (applicable in Western Europe)
Observe the procedure below before the battery is replaced.
•
Check that the packaging of the new battery is still unopened and that the production date on the
battery is not further back than 2 years before the current date. Open the packaging and keep the
battery within easy reach.
•
Unscrew the two bolts on the front of UNIGAS 300 until the bolt heads are roughly level with the
front. Then open the housing. The seal may stick, so it may take some effort to open the housing.
Then close the housing, but do not tighten the bolts yet.
•
Select menu item 10 (battery) on the display and perform the actions given below:
10. Battery
►
Screen 10-1: Status
►
Screen 10-1-1: Status: U batt, AH used, AH new
►
Screen 10-2: Replace
►
Screen 10-2-2: Replace now
►
Screen 10-2-2-1: Open cover and replace
battery within 10 s
•
UNIGAS 300 is set to sleep mode at the moment when the housing is opened. That shows from the
display going blank. Now first take the battery connector from UNIGAS 300. Then quickly place the
connector of the new battery. Now take the old battery from the battery holder and place the new
battery in the battery holder.
Remark: It the opening of the housing takes too long, UNIGAS 300 will break off the procedure. When
the housing is opened, the display will not go blank. Repeat the procedure.
•
The sleep mode will end at closing of the casing or after 1 minute waiting time.
•
Close the housing of UNIGAS 300, screw the housing tight and operate the push buttons to check the