CLEARANCES TTO C
COMBUSTIBLES
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given
below.
A non-combustible shelf may be fitted to within 30mm of the top edge of the decorative stone effect frame.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the frame of the
appliance, providing the forward projection does not exceed 100mm (4in).
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock, blown vinyl and
embossed paper) positioned too close to the appliance may discolour or scorch.
VENTILATION
No ppurposse pprovided vventilation iiss nnormally rrequired ffor tthiss aappliancce. The requirements of other appliances
operating in the same space or room, and the results of a spillage test must be taken into consideration when
assessing ventilation requirements, this will have been carried out by your CORGI registered installer.
For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules in force.
OPERATING TTHE FFIRE
The control knob of the fire is marked as follows ;
The pilot is visible at the rear of the burner. Push in and turn the control
knob to the SPARK position, and hold there for a few seconds.
Continue turning anti-clockwise through the spark click, ensuring the
pilot has lit. If not, return the knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob depressed for
approximately ten seconds. Now release the knob and the pilot should
stay alight. If not, retry ignition. If the pilot is extinguished during use,
wait three minutes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and con-
tinue turning anti-clockwise to the large flame position. The main burn-
er should light after a few seconds.
To decrease the setting to LOW, turn the control knob clockwise to the low flame setting. The flame height may
be adjusted as desired between high and low settings by turning the control knob to the required position
between ‘HIGH’ and ‘LOW’.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot
position and release.
To turn the fire OFF, keep the knob pressed in, return to the off position and release.
2
2.0
3.0
4.0
Maximum ddepth oof sshelf M
Minimum ddisstancce ffrom ssurfacce oof hhearth
to uundersside oof sshelf
100mm (4in)
860 mm (34 in)
150mm (6in)
970 mm (38 in)
203mm (8in)
1020 mm (40 in)
‘OFF’ position
‘SPARK’ position
‘LOW’ position
‘HIGH’ position