33740-9-1015
Page 15
33740-9-1015
Page 14
ELECTRICAL CONSIDERATIONS
CAUTION
All wiring should be done by a qualified electrician and shall be
in compliance with all local, city and state building codes. Before
making the electrical connection, make sure the main power
supply is disconnected. The appliance, when installed, must be
electrically grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical Code ANSI/
NFPA 70 (Latest Edition).
ORANGE
PILOT
GAS CONTROL VALVE
ORANGE
GREEN
YELLOW
WHITE
BLACK
WHITE
OPTIONAL BLOWER
FUSE
BLACK
L
N
G
WHITE
GREEN
TO JUNCTION
BOX
AUX.
LOOP
RECEIVER
MODULE
SPLIT FLOW SOLENOID
SLEEVE
USER INTERFACE/
BATTERY HOLDER
LEARN
BUTTON
IGNITOR
FLAME SENSOR
3.15
AMP
The user interface/battery holder must be mounted within a distance
allowed by the attached 12 foot harness. As shipped, this harness is
already fed through a strain relief on the bottom of the component
access box and is attached to the User Interface/Battery Holder.
NOTE:
If an auxiliary device is to be used, its wiring may be fed
through the junction box strain relief. Auxiliary device amperage
limit is 5 amps.
NOTE:
A one inch diameter hole should be use to pass wiring through
studs.
VERTICAL
FRAMING
MEMBER
USER INTERFACE
HARNESS
USER INTERFACE/
BATTERY HOLDER
MUST BE INSTALLED
INTO WALL JUNCTION
BOX. (ORANGE LOW-
VOLTAGE BOX
RECOMMENDED.)
COMPONENT
ACCESS BOX
ELECTRICAL POWER TO UNIT
JUNCTION BOX / CONTROL MODULE
Figure 13
Figure 14
A factory installed junction box is located on the lower right side of
the fireplace. Wiring must be fed to the junction box and attached
with wire nuts to the control module power leads already fed into
the junction box.
Attach black to black and white to white. The ground wire should
be attached to the green control module lead.
INSTALLATION
Framing and Finishing
CAUTION
MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING
METHODS, AND WALL COVERING DETAILS BEFORE
FRAMING CONSTRUCTION BEGINS.
1. Choose unit location.
2. Frame in fireplace with a header across the top.
NOTE:
Fireplace framing can be built before or after the fireplace
is set in place. Framing should be positioned to accommodate
wall covering and fireplace facing material. The fireplace framing
should be constructed of 2 x 4 lumber. The framing headers
may rest on the fireplace standoffs. Refer to
Figures 15 and
16
for minimum framing dimensions.
NOTE:
When installing this unit against exterior wall, insulate to
applicable insulation codes.
3. Remove two screws which are accessed through the clearance
holes in the rear heat shield.
See Figure 17
. Hand bend the
rear stand-off as shown in
Figure 18 and Figure 19.
Replace
the two screws previously removed to secure stand-off to unit.
3. Attach fireplace to frame using nailing flange. Preset depth to
suit facing material (adjustable to 1/2 inch or 5/8 inch depths).
See Figures 20 to 22.
*Adjust accordingly if chase is finished with drywall or other material.
Figure 15
Figure 16
Figure 17