33740-9-1015
Page 43
33740-9-1015
Page 42
Figure 54
COMpONENT WIRING DIAGRAM
ORANGE
PILOT
GAS CONTROL VALVE
ORANGE
GREEN
YELLOW
WHITE
BLACK
WHITE
OPTIONAL BLOWER
FUSE
BLACK
L
N
G
WHITE
GREEN
TO JUNCTION
BOX
AUX.
A
C
B
E
LOOP
SPLIT FLOW SOLENOID
SLEEVE
USER INTERFACE/
BATTERY HOLDER
3.15
AMP
LEARN
BUTTON
IGNITOR
FLAME SENSOR
D
RECEIVER
MODULE
INDEX NUMBER
DESCRIpTION
pART NUMBER
A
WIRE HARNESS, LIGHT SOCKETS
R11860
B
WIRE HARNESS, MODULE TO USER INTERFACE
R11552
C
WIRE HARNESS, SPLIT-FLOW SOLENOID TO MODULE
R11551
D
WIRE HARNESS, LIGHTS AND BLOWER TO MODULE
R11741
E
WIRE HARNESS, JUNCTION BOX TO MODULE
R11730
MULTIFUNCTION REMOTE OpERATING INSTRUCTIONS
Technical Data
Remote Control
Supply voltage
4.5 V (three 1.5 V AAA batteries)
Ambient temperature ratings
0-50°C (32 - 122°F)
Radio frequency
315 MHz
WARNING
THE TRANSMITTER AND RECEIVER ARE RADIO FRE-
QUENCY DEVICES. PLACING THE RECEIVER IN OR NEAR
METAL MAY SEVERELY REDUCE THE SIGNAL RANGE.
WARNING
TURN “OFF” THE MAIN GAS SUPPLY AND ELECTRICAL
SUPPLY TO THE APPLIANCE DURING INSTALLATION AND/
OR MAINTENANCE OF THE RECEIVER DEVICE.
WARNING
FIRE HAZARD. CAN CAUSE SEVERE INjURY OR DEATH.
THE RECEIVER CAUSES IGNITION OF THE APPLIANCE.
THE APPLIANCE CAN TURN ON SUDDENLY. KEEP AWAY
FROM THE APPLIANCE BURNER WHEN OPERATING THE
REMOTE SYSTEM OR ACTIVATING MANUAL BYPASS OF
THE REMOTE SYSTEM.
CAUTION
pROpERTY DAMAGE HAZARD.
EXCESSIVE HEAT CAN CAUSE pROpERTY DAMAGE.
THE APPLIANCE CAN STAY LIT FOR MANY HOURS. TURN
OFF THE APPLIANCE IF IT IS NOT GOING TO BE AT-
TENDED FOR ANY LENGTH OF TIME. ALWAYS PLACE THE
TRANSMITTER WHERE CHILDREN CAN NOT REACH IT.
Figure 55
Figure 56
NOTE:
This control system includes a Battery Back-up pack that
allows the Fireplace to operate in the event of a power outage.
NOTE:
The Accent Light and/or Blower features will not operate
during a power outage.
NOTE:
Replace all Batteries at least once each year, preferably
before at the beginning of the season.
CAUTION
FIRE OR EXpLOSION HAZARD.
CAN CAUSE PROPERTY DAMAGE, SEVER INJURY OR
DEATH. DO NOT ATTEMPT TO TAKE APART THE GAS CON-
TROL OR TO CLEAN IT. IMPROPER ASSEMBLY AND CLEAN-
ING CAN CAUSE UNRELIABLE OPERATION.