TEST
In resistance scale, you must check the continuity between its terminals.
Continuity must be present with rod pressed (Lid closed), and not present with rod free.
Open and close the Lid several times with Micro Switch within its housing. No intermittence must be present.
Rod
Continuity (Ohms -
Ω
)
Pressed
0
Free
∞
Before changing Micro Switch check:
-
Continuity on Wiring Harness;
-
Its correct position within housing related to Lid;
-
Make a visual inspection on Micro Switch. Plastic knob should not be loose and plastic lid should not be
melted
DISMOUNTING
-
Release the screw;
-
Remove the switch.
5.8 – Drainage Electric Pump
Located below of the tub, it performs the water drainage operation.
TEST
1. With a Multimeter set in resistance scale, measure continuity at component terminals:
Voltage
Continuity (Ohms -
Ω
)
220V – 60Hz
95 to 112
Before changing Electrical Pump check:
-
Continuity on Wiring Harness;
-
Wiring Harness is connected correctly;
-
If it is clogging or locked by foreign objects.