6-4
"Quick Test" Mode for Electronic Range Control
Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the
control will exit the quick test mode.
1.
Press and hold
CANCEL and BROIL pads for 3 seconds.
2. Once the control has entered the "Quick Test" mode, release both pads.
3. Press each of the following pads indicated in the table below.
NOTE: First time one of following pads are pressed it will activate the response.
The second time the pad is pressed it will deactivate the response.
NOTE: This mode can only be entered within the first 5 minutes after power up.
NOTE: If the temperature sensor is greater than 400
°
F and the Quick Test mode will be disabled if the
temperature sensor reaches 400
°
F while under test.
Display will indicate the following:
n
o
it
a
r
e
p
O
y
e
K
[Bake]
Bake relay activated
[Broil]
Broil relay activated
[Keep Warm]
DLB relay activated
[Cook&Hold]
Last Diagnostic Code displayed
[Clean]
Beep sounds
[Delay] (M1)
EEPROM Version Number displayed
[Timer]
Main Code Version Number displayed
[Clock]
All Segments On
[More +]
Even Segments On
[Less –]
Odd Segments On
[Cancel]
End Factory Test Mode
Diagnostic Code Display Mode can only be started within 30 seconds when powering up the control.