4-12
REMOVING DOOR LATCH ASSEMBLY
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug range or disconnect power.
2. Pull the range out of it’s mounting location
so that you access the rear of the unit.
3. Remove rear panel. (see removing rear
panel page 4-6 for procedure).
4. Remove cooktop. (see removing cooktop
and coil element receptacles page 4-4 for
procedure).
Burner Box
Bottom
5. Remove four screws from burner box at-
taching it to unit.
Burner Box
Screws
6. Remove burner box bottom from unit.
Door Latch
Assembly
Содержание RY160LXTQ