FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
34
Removing the Bulk Dispenser
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
from section Removing the Console.
4.
Using a 1/4" nut driver remove the ACU screw and slide ACU to the left.
5.
Remove 1/4" (6 mm) screw as shown in below figure.
6.
Push in on harness retainer and lift to disconnect bulk dispense reed
switch harness.
7.
Remove 1/4" (6 mm) screw as shown in below figure.
8.
Remove inlet valve assembly by removing two (2) 1/4" (6 mm) screws
and disconnecting valve harness from ACU. Lift the valve assembly and
remove from dispenser housing.
9.
Complete the steps
from section Lifting the Top Panel.
10.
Lift the bulk drawer and remove it from housing.
A
B
A. ACU Screw
B. Dispenser Housing
Screw