Service Competence Center
Ind
u
ctio
n
G
0
Service
Code
Type
Repair suggestions:
shown on
display
Failure description
of failure
Points to check subsequently until the appliance starts to work properly
again.
Failure description / repair
Troubleshooting
F-60
E53 - USIF I/O Button
error
Type 3 1)
Replace the USIF
F-60
E57 - There is an access
E2PROM memory error The
memory is damaged.
Type 3
Replace the USIF
F-61
60730 Micro register
error
Type 2 1)
Switch off and on the cooktop
2)
Replace the power unit board
F-62
60730 Micro Ram error
Type 2 1)
Switch off and on the cooktop
2)
Replace the power unit board
F-63
60730 Micro FLASH
error
Type 2
Switch off and on the cooktop
Replace the power unit board
F-72
CH1 / CH2 Io Port Error
Type 2 1)
Switch off and on the cooktop
2)
Replace the power unit board
F-73
60730 Micro Program
Flow Error
Type 2
Switch off and on the cooktop
Replace the power unit board
F-77
Coil 1/2 NTC Stuck
Type 2 1)
Switch off and on the cooktop
2)
Replace the power unit board
Содержание G0
Страница 1: ... Service Competence Center Induction G0 Induction cooktop G0 ...
Страница 8: ... Service Competence Center Installation Installation Induction G0 ...
Страница 9: ... Service Competence Center Installation Installation Induction G0 ...
Страница 35: ... Service Competence Center Components overview components Induction G0 ...
Страница 36: ... Service Competence Center Components overview components Induction G0 ...
Страница 38: ... Service Competence Center Components overview converter board Induction G0 fan IPC2 Filter board IPC1 ...
Страница 39: ... Service Competence Center Components overview cable connections Induction G0 ...
Страница 44: ... Service Competence Center Components Zone NTC PTN 312 Induction G0 ...
Страница 50: ... Service Competence Center Housing Touch control Zone Fan Converter board Repair Guide Line Induction G0 ...
Страница 54: ... Service Competence Center Repair guide line Touch control disassembly User interface connection Induction G0 ...
Страница 72: ... Service Competence Center Trouble Shooting Wiring Diagram Induction G0 ...
Страница 73: ... Service Competence Center Range overview 12NC breakdown 7 safety points Marketing information Induction G0 ...
Страница 74: ... Service Competence Center Induction G0 Marketing Range overview ...
Страница 75: ... Service Competence Center Induction G0 Marketing Control panel variants ...
Страница 79: ... Service Competence Center Documents Induction G0 I F U ...