background image

CONNECT

DRYER TO

EXHAUST

SYSTEM

Secure all joints with clamps or duct
tape. DO NOT use sheet metal
screws or other fastening means
which extend into the duct to attach
exhaust pipe joints. They could
catch lint and reduce the efficiency
of the exhaust system.

IMPORTANT: Keep exhaust duct
as short as possible.

Be sure old ducts are clean before
installing your new dryer.

To prevent backdraft when dryer is
not in operation, outer end of
exhaust pipe must have a weather
hood with hinged dampers (obtain
locally).

Weather hood should be installed
at least 12" (30.5 cm) above the
ground. Higher clearances may be
necessary in areas where heavy
snowfall can occur.

No extra system length
consideration is necessary when
exhausting through the roof. Use

MAXIMUM EXHAUST LENGTH

table to calculate system length.
Use a roof cap that provides air
flow equal to weather hood.

Exhaust Directions

Dryer can be exhausted to the
outdoors through the back, right, or
bottom of the dryer. Gas dryers
cannot be vented out the left
side because of the burner
housing.

Dryer is shipped from factory ready
for rear exhaust. No kits required.

To exhaust dryer through sides or
bottom, install a DK1 Sales
Accessory (Directional Exhaust Kit
528P3). Available as optional
equipment at extra cost.

CONNECT GAS

SUPPLY

Installation

Instructions

Gas Dryer

Keep instructions for future

reference. Be sure manual

stays with dryer.

3

2

Exhaust System Materials

Exhaust duct must be four inches
(10.2 cm) in diameter without
obstructions. Rigid metal duct is
recommended. Non-combustible
semirigid flexible metal duct is
acceptable.

DO NOT use plastic pipe, foil pipe,
or flexible plastic pipe, because it
contributes to poor drying
performance and collects lint, which
can lead to a fire hazard. To identify
flexible foil or plastic duct, pinch the
coils of the duct between your
fingers. If the coils can be brought
together, do not use the duct.

Do Not Use

Use

Rigid Metal

 Semirigid Metal

Flexible Foil

Plastic

4" (10.16 cm)

4" (10.16 cm)

Recommended Weather Hood

2-1/2" (6.35 cm)

Recommended 

for Short Runs Only

POSITION AND

LEVEL DRYER

Place dryer in position, adjust all
legs (4) until dryer is level side to
side and front to back.

5

REMOVE PARTS

AND CLEAN

DRYER DRUM

Wipe drum with clean rag and soap
diluted in warm water to remove any
oil used in manufacturing. Make a
paste of laundry detergent and clean
drum if necessary.

1

Questions?

See 

Owner’s Manual 

or

call Amana Consumer Affairs

Department 1-800-843-0304

Optional Kits

Kits are available at extra cost through
your Amana dealer or
Amana factory 1-800-843-0304.

Directional Exhaust Kit
DK1 Sales Accessory (Directional
Exhaust Kit #528P3).

Flexible Metal Vent Kit
Exhausting the dryer in hard-to-reach
locations can be accomplished by
installing Kit # 521P3.

Manufactured (Mobile) Home
Installation Kit

Manufactured home anchor Kit
#526P3.

Propane Gas Conversion Kit

LPK1 Sales Accessory (L.P./Propane
Kit # 649P3).

Test for Gas

Leaks

After final gas
connection is made,
turn on manual gas
valve and test all connections in gas
supply piping for gas leaks. Leak
testing of the appliance shall be
conducted according to the
manufacturer’s instructions.

1.

Place soap suds on connections.

2.

If bubbles appear, a leak is
present. Shut off gas supply
valve.

3.

Tighten joint if leak is at factory
fitting.
• If leak is not at factory fitting,

unscrew, apply more joint
compound, and tighten to
correct leak.

4.

Retest connection for leak after
tightening or adding joint
compound.
• Retest any connections that

were disturbed.

Altitude

Ft (M)

Orifice

Size #

Part

number

3000 (915)

43

503778

6000 (1830)

44

58719

8000 (2440)

45

503779

9000 (2740)

46

503780

10000(3050)

47

503781

For proper operation at

altitudes above 2,500 feet

The natural gas valve spud orifice
size must be reduced to ensure
complete combustion. See table.

Connect gas supply to dryer using a new stainless steel flexible connector
or hard pipe (check local codes) according to illustration. Test for leaks and
check burner flame after gas supply is connected. See 

Checking Burner

Flame 

section on next page.

• Dryer must be connected to type of gas as shown on nameplate located

in the door recess.

• Use pipe joint compound insoluble on LP (propane) Gas, or Teflon tape,

on all pipe threads.

• Purge air and sediment from gas supply line before connecting it to the

dryer. Before tightening the connection, purge remaining air from gas line
to dryer until odor of gas is detected. This step is required to prevent gas
valve contamination.

4

CONNECT

POWER CORD

TO

ELECTRICITY

See 

Installation Requirements

section. Plug dryer into
3-prong grounded outlet only.

You'll Need a Few Things Before You Begin

L.P./Propane

DO NOT connect dryer to L.P./
Propane gas service without
converting the gas valve. An LPK1
Sales Accessory L.P./Propane Gas
Conversion Kit 649P3 must be
installed.

Duct Tape

Wrench

Screw 

Drivers

Level

Teflon Tape or 

Joint Compound

Stainless Steel 

or Hard Pipe

Gas Connector

To reverse the direction that the
door opens, see the Owner’s
Manual.

Maximum Exhaust Length

Rigid Metal Duct

Number of
90º Elbows

Weather Hood
4-inch Opening

Weather Hood
2½-inch Opening

0

44 feet (13.4 m)

34 feet (10.4 m)

1

34 feet (10.4 m)

26 feet (7.9 m)

2

26 feet (7.9 m)

20 feet (6.1 m)

3

20 feet (6.1 m)

14 feet (4.3 m)

Flexible Metal Duct

Number of
90º Elbows

Weather Hood
4-inch Opening

Weather Hood
2½-inch Opening

0

24 feet (7.3 m)

20 feet (6.1 m)

1

20 feet (6.1 m)

16 feet (4.9 m)

2

16 feet (4.9 m)

12 feet (3.7 m)

3

12 feet (3.7 m)

8 feet (2.4 m)

NOTE: Deduct 6 feet (1.8 m) for each additional elbow.

Level

Dryer

Base

Leveling

Leg

3

/

8

" NPT gas 

connection

Black iron pipe

Shorter than 20' (6.1 m) - use 

3

/

8

" pipe 

Longer than 20' (6.1 m) - use 

1

/

2

" pipe

Use new stainless steel flexible connector

 

only  if allowed by local codes (Use Design A.G.A. certified connector)

1

/

8

" NPT pipe plug

(for checking inlet 

gas pressure)

Install Equipment 

shut-off valve

 

 within 6' (1.8 m) 

of dryer.