Service Competence Center
Ind
u
ctio
n
G
0
Service
Code
Type
Repair suggestions:
shown on
display
Failure description
of failure
Points to check subsequently until the appliance starts to work properly
again.
Failure description / repair
Troubleshooting
F-47
E39 - One IPC only is
not responding within a time
T_to_have_response_
from_IPC
when it is polled
Type 2 1)
Check if the harness / wires ( WIDE cables) are well connected in the related
connectors.
2)
If this does not fix the appliance then: Replace the related IPC
3)
If replacing the IPC with a new one did not fix the appliance, then check fuse
on filter boards. If interrupted replace fuse component.
4)
If replacing the fuse with a new one did not fix the appliance change the Filter
board .
F-47
E47 - WIDE
communication error.
Communication
between USIF and all the
IPCs is not working.
Type 3 1)
Check if the harness / wires ( WIDE cables) are well connected in the related
connectors. If this does not fix the appliance then:
2)
Replace the USIF
F-48
IPC WIDE
communication error / live
tag
Type 2 1)
Check the wire between USIF and IPC
2)
Replace the power unit board
F-49
IPC WIDE
communication error / CRC
error
Type 2 1)
Check the wire between USIF and IPC
2)
Replace the power unit board
F-56
E56 - Wrong or invalid
USIF configuration.
Type 3 1)
Configure the USIF. If this does not fix the appliance then:
2)
Replace the USIF with a new one
F-58
E58 - Wrong or invalid
IPC configuration.
Type 2 1)
Configure the related IPC If this does not fix the appliance then:
2)
Replace the related IPC with a new one
Содержание G0
Страница 1: ... Service Competence Center Induction G0 Induction cooktop G0 ...
Страница 8: ... Service Competence Center Installation Installation Induction G0 ...
Страница 9: ... Service Competence Center Installation Installation Induction G0 ...
Страница 35: ... Service Competence Center Components overview components Induction G0 ...
Страница 36: ... Service Competence Center Components overview components Induction G0 ...
Страница 38: ... Service Competence Center Components overview converter board Induction G0 fan IPC2 Filter board IPC1 ...
Страница 39: ... Service Competence Center Components overview cable connections Induction G0 ...
Страница 44: ... Service Competence Center Components Zone NTC PTN 312 Induction G0 ...
Страница 50: ... Service Competence Center Housing Touch control Zone Fan Converter board Repair Guide Line Induction G0 ...
Страница 54: ... Service Competence Center Repair guide line Touch control disassembly User interface connection Induction G0 ...
Страница 72: ... Service Competence Center Trouble Shooting Wiring Diagram Induction G0 ...
Страница 73: ... Service Competence Center Range overview 12NC breakdown 7 safety points Marketing information Induction G0 ...
Страница 74: ... Service Competence Center Induction G0 Marketing Range overview ...
Страница 75: ... Service Competence Center Induction G0 Marketing Control panel variants ...
Страница 79: ... Service Competence Center Documents Induction G0 I F U ...