Service Competence Center
Ind
u
ctio
n
G
0
Service
Code
Type
Repair suggestions:
shown on
display
Failure description
of failure
Points to check subsequently until the appliance starts to work properly
again.
Failure description / repair
Troubleshooting
F-25
Fan Stuck on IPC #
Type 3 1)
Check Fan connection
– if the connector is plugged in well or not.
2)
Replace the Fan with a new one.
3)
If replacing the fan with a new one did not fix the appliance, then the old fan is
still good. Put it back in the appliance. Change the IPC interested in the failure.
F-33
Heatsink NTC open
Type 2 1)
Replace the power unit board
F-34
Heatsink NTC shorted
Type 2 1)
Replace the power unit board
F-36
Coil #
– temperature
sensor short-circuited
NTC temp value is out
of the spec range.
Type 1 1)
Check if the NTC coil that is showing the failure is well plugged in the proper
connector.
2)
Replace the interested Coil with a new one.
3)
If replacing the Coil with a new one did not fix the appliance, then the old coil is
still good. Put it back in the appliance. Change the IPC interested in the failure
F-37
Coil #
– temperature
sensor Open-circuited
NTC temp value is out
of the spec range.
Type 1 1)
Check if the NTC coil that is showing the failure is well plugged in the proper
connector.
2)
Replace the interested Coil with a new one.
3)
If replacing the Coil with a new one did not fix the appliance, then the old coil is
still good. Put it back in the appliance. Change the IPC interested in the failure
F-46
IPC WIDE
communication error/ Time
Out UI/ TSM
Type 2 1)
Check the wire between USIF and IPC
2)
Replace the power unit board
F-47
E35 - After 3 seconds,
10,5 volts line from one IPC
is missing
Type 2 1)
Check the wire between USIF and IPC
2)
Replace the related IPC
3)
If replacing the IPC with a new one did not fix the appliance, then check fuse on
filter boards. If interrupted replace fuse component.
4)
If replacing the fuse with a new one did not fix the appliance change the Filter
board .
Содержание G0
Страница 1: ... Service Competence Center Induction G0 Induction cooktop G0 ...
Страница 8: ... Service Competence Center Installation Installation Induction G0 ...
Страница 9: ... Service Competence Center Installation Installation Induction G0 ...
Страница 35: ... Service Competence Center Components overview components Induction G0 ...
Страница 36: ... Service Competence Center Components overview components Induction G0 ...
Страница 38: ... Service Competence Center Components overview converter board Induction G0 fan IPC2 Filter board IPC1 ...
Страница 39: ... Service Competence Center Components overview cable connections Induction G0 ...
Страница 44: ... Service Competence Center Components Zone NTC PTN 312 Induction G0 ...
Страница 50: ... Service Competence Center Housing Touch control Zone Fan Converter board Repair Guide Line Induction G0 ...
Страница 54: ... Service Competence Center Repair guide line Touch control disassembly User interface connection Induction G0 ...
Страница 72: ... Service Competence Center Trouble Shooting Wiring Diagram Induction G0 ...
Страница 73: ... Service Competence Center Range overview 12NC breakdown 7 safety points Marketing information Induction G0 ...
Страница 74: ... Service Competence Center Induction G0 Marketing Range overview ...
Страница 75: ... Service Competence Center Induction G0 Marketing Control panel variants ...
Страница 79: ... Service Competence Center Documents Induction G0 I F U ...