I.  B.  11150-2 

RECEIVING 

• 

INSTALLATION 

• 

MAINTENANCE 

INSTRUCTIONS 

MODEL  P0-6  6- P0-12 

THE 

ELECTRONIC  AIR  CLEANER 

OIL  MIST  CONTROL  UNIT 

PRECIPITRONOilMist Control  Unit  is an elec­

tronic  air  cleaning  apparatus  used  to  remove  oil 

mist  from  the  machine  room air.  To produce the 

desired  results, 

it 

must be properly  installed and 

maintained.  This  Instruction  Book  gives correct 

steps  and  precautions  to  be  taken.  It  should be 

carefully  read  before  the  unit  is  installed  or op­

erated. 

SUPERSEDES 

1.  B.  1450·1 

EFFECTIVE  SEPTEMBER, 

1953 

EFFECTIVE  MAY, 

1957 

WESTINGHOUSE  ELECTRIC  CORPORATION 

HYDE  PARK 

• 

STURTEVANT  DIVISION 

• 

BOSTON  36,  MASS. 

www 

. ElectricalPartManuals 

. com 

Содержание P0-6

Страница 1: ...rom the machine room air To produce the desired results it must be properly installed and maintained This Instruction Book gives correct steps and precautions to be taken It should be carefully read before the unit is installed or op erated SUPERSEDES 1 B 1450 1 EFFECTIVE SEPTEMBER 1953 EFFECTIVE MAY 1957 WESTINGHOUSE ELECTRIC CORPORATION HYDE PARK STURTEVANT DIVISION BOSTON 36 MASS w w w E l e c ...

Страница 2: ...TYPICAL INSTALLATIONS MACHINE MOUNTED CEILING MOUNTED FLOOR MOUNTED w w w E l e c t r i c a l P a r t M a n u a l s c o m ...

Страница 3: ...ith tapped FIG 1 P0 6 UNIT FIG 2 P0 12 UNIT holes at the four corners to accommodate 3 8 16 mounting bolts A minimum of 30 of clearance space in front of the cabinet door 10 on the window side of the power pack and 10 above the overall height of the unit is required for service access Internal Packing When unit is located open the cabinet door and remove cardboard packing between the ionizer and d...

Страница 4: ... loss when designing the overall duct system Drain Connections A 3 4 i p s female drain connection is located at the left lower side of the c a b i n e t Suitable plumbing is required to drain collected oil to the machine coolant sump or other disposal facility Piping should be pitched to assure gravity flow from the unit A U trap should be installed in the drain pipe to prevent blocking re verse ...

Страница 5: ...cted d Rectifier tube does not glow Check tube socket contact try replacing tube check transfor mer wiring and winding See Normal Operation e Faulty ammeter Replace meter 6 Ammeter reads high a High supply voltage See Power Supply Power Red range above Pack Wiring 0 6 amps b Broken ionizer wire Replace wire being sure to re move broken pieces c Dirty cells or ionizer See Cleaning Also too much moi...

Страница 6: ... cells ionizers and filters should be inspected weekly for cleanli ness Experience after a few inspections will deter mine the need for regular cleanings In any event it is good practiceto inspect the internal components at least monthly If a layer of dirt or hardened oil is observed on cell plates ionizer tubes ionizer wires insulators or filters the dirty components should be removed and thoroug...

Страница 7: ...ceive electrostatic charges Ionizer Wires Attached near the center of each wire is a dampener ball which prevents the wire from vibrating during operation These wires are supplied complete with dampeners and pre looped ends from the factory and must be completely re placed if the wire breaks or the dampener becomes damaged or loose To check the effectiveness o f 6 FIG 6 IONIZER the dampener pluck ...

Страница 8: ... p o w e r pack removing power pack mounting screws relocating highvoltage cables and wiring hardware and reconnecting power pack to the other side of cabinet Cover unused wiring and mounting holes with the plug buttons and dummy mounting screws to prevent air leakage On early design units unscrew the inspection window and move to the opposite side Note Mark each lead when it is disconnected to a ...