50-kw
5-kw
Function
S 3E Left S3E Right T o trans fer transmis s ion line between
50- and 5-kw outputs and to ground un
us ed circu its .
S3C
S4C
S 3G
S4G
To trans fer output of unit C b etween
input to units D and E, and input to
harmonic suppress ion network of unit C,
and to ground unused circu it .
To transfer bias connection to unit C
b etween unit
K
and Unit G .
S 56P
S 5 5P
To trans fer control circu it conections ;
also to transfer 460-volt su�ply be
tween bias rectifiers, units K and G.
S63P
S64P
To transfer control c ircu it connections ;
also to trans fer 460-volt regulated sup
ply between 50-kw and 5-kw high-vo ltage
transformers .
(c ) D6C, a SPDT switch located in Unit C which c on-
neots the plate circuit of this unit to e ither
the 50-kw fi lter condens er as semb ly (FC50P ) or
the 5-kw as semb ly (FC51P ) .
( 5 ) Leave the 5-kw encl osur e, clos e door, and open the
5-kw rectifier grounding swit ch.
( 6 ) Clos e 11H. V. R ectifier" switch D4F.
This places the transmitter back on the air at 5-kw,
without further adjustment . If desired, operations ( 1 ) and
( 6 ) ab ove may b e omitted, s ince if switch D4F is left
clos e d, operation of the grounding swit che s will s erve to
remove and restore the carrier .
After the ab ove procedure the fi laments of units D, E,
H and K, and the motor blower in Unit H, are still 110Nn .
The 46 0-volt supply to the two rectifiers may be cut off by
73