high-voltage grounding switch open, all the gate lamps will
light and the b ias contactor S 56P wi ll operate, energiz ing
the b ias rectifiers
(
Unit K
)
and lighting the "Mod
•
.Amp.
B ias " lamp
(
E21F
)
and "Power .Amp. Bias " lamp
(
E22F
)
. The
bias voltmeters
(
M2F, M3F and M4F
)
should indicate the proper
bias voltages .
Oscillator-Ampl ifier Filaments
The osci llator-amplifier fi laments may be energized at
any time but preferab ly should be started a few minutes be
fore the rectifier filaments have been completely prehe ated.
Throw the "Osc
•
.Amp . Filaments " switch
(
DlOF
)
to 110N11 oper
ating contactor S 54P. Keep all switches in the os c illator
amplifier itself in the "ON" pos iti on.
Water
Keep the s afety dis connect switches D3. 1W and D3. 2W
cl osed except when servic ing the associated cooler. Close
the switch D4. 1W or D4. 2W depending on the particular cooler
it is desired to operate. Press the push butt on on line
starter Dl . lW or Dl . 2W, depending on t�e pump it is desired
to have operate, to the 110N11 position. Set the valves of
the water system as instructed in the section covering this
sys tem; then place the system in operation by clos ing the
switch 11Water System"
(
D2F
)
to 110N11 • S 51P operates, start
ing the cooler motor and operating the l ine s tarter which
starts a pump.
When the proper water fl ovv is obtained t�a flow relays
WDlW and WD2W and relays S2W and SlF operate . Lamp E8F
"Water System" lights and the green lamp above the switch
"Amplifier Filaments"
(
D3F
)
l ights indicating the filaments
may be energized. In col d weather the cooler motor may be
started by D4W after the amplifier fi laments are energiz ed
as described in the section covering the "Water System" .
70