connection), comprising the three-phase plate rectifier. It
also includes a single-phase full-wave rectifier, supplying
grid voltage to the two tubes in Unit
O,
for emergency
operation at 5-kw.
Power Distribution Cabinet
This unit contains
contactors, disconnect switches ann circuit breakers for the
various 460-volt circuits of the transmitter, filament start
ing resistors for the 50-kw stage, and power-supply trans
formers for the preliminary stages.
5-kw Plate Transformer
This is a three-phase
plate-supply transformer, supplied with 460 volts regulated
power for emergency 5-k w operation.
D-9977 4 Condenser and Switch
This
assem bly includes the high-voltage condenser for filtering
the output of Unit
G,
its charging resistor and associated
contactor.
Filter Choke Coil
This coil to
gether with the above condenser forms the plate-supply fil
ter for Unit C, for emergency operation at 5 -kw output .
Outside Enclosures
(Unit
This equipment con
sists of two water-pumps (one a spare), two air-blast radia
tors with their blower motors and associated disconnects,
a tank, and the necessary valves and fittings.
The insulat
ing ceramic piping for the power amplifier stage is usually
supported below the basement ceiling.
Transformer
This equipment consists of three high-voltage plate
supply transformers, and an induction regulator (T 56P) for
varying the primary supply voltage to these transformers.
These units have been designed for out-of-door or in-door
mounting.