10
1.
Insert
positive
and
negative
wires
into
V+
and
V
‐
contacts
respectively
of
the
terminal
block
connector
2.
Tighten
the
wire
‐
clamp
screws
to
prevent
DC
wires
from
being
loosened.
3.
Power
1
and
Power
2
support
power
redundancy
and
polarity
reverse
protection
functions.
4.
Positive
and
negative
power
system
inputs
are
both
accepted,
but
Power
1
and
Power
2
must
apply
the
same
mode.
Note
1:
It
is
a
good
practice
to
turn
off
input
and
load
power,
and
to
unplug
power
terminal
block
before
making
wire
connections.
Otherwise,
your
screwdriver
blade
can
inadvertently
short
your
terminal
connections
to
the
grounded
enclosure.
Note
2:
The
range
of
the
suitable
electric
wire
is
from
12
to
24
AWG.
Note
3:
If
the
2
power
inputs
are
connected,
the
switch
will
be
powered
from
the
highest
connected
voltage.
The
unit
will
alarm
for
loss
of
power,
either
PWR1
or
PWR2.
Note
4:
To
use
the
UL
Listed
Power
supply
with
output
Rating
12
‐
48
Vdc,
minimum
1
A
2.3
Wiring
Digital
Input
The
switch
provides
2
digital
inputs.
It
allows
users
to
connect
the
termination
units’
digital
output
and
manage/monitor
the
status
of
the
connected
unit.
The
Digital
Input
pin
can
be
pulled
high
or
low;
thus
the
connected
equipments