19
6195-2201
Defined values
The following <fac> values are supported:
”PS”:
SIM lock facility with a 8 digits password.
”SC”:
PIN enable (<mode> = 1) / disable (<mode> = 0)
”AO”:
BAOC (Barr All Outgoing Calls)
”OI”:
BOIC (Barr Outgoing International Calls)
”OX”:
BOIC-exHC (Barr Outg. Internat Calls except to Home Country)
”AI”:
BAIC (Barr All Incoming Calls)
”IR”:
BIC-Roam (Barr Inc. when Roaming outside Home Country)
”AB”:
All Barring services
”AG”:
All outGoing barring services
”AC”:
All inComing barring services
”PN”:
Network lock with a 8 digits password (NCK).
”FD”:
SIM Fixed Dialling Numbers (FDN) memory feature
(PIN2 is required as <password>)
<mode>
0: unlock the facility
1: lock the facility
2: query status
<class>
: A facility status can be changed for only one class, or for all classes
(7 or omitted).
<class>
1: Voice (telephony)
2: Data (refer to all bearer services)
4: Fax (facsimile services)
8: Short Message service
7: equal to all classes (Default value)
Any attempt to combine different classes will result in activation/desactivation/
interrogation of all classes.
The password maximum length is given with the AT+CPWD=? command.