6195-2201
+CLCK – Facility lock
This command shall be used by the application to lock, unlock or interrogate a ME
or network facility <fac>.
Command syntax: AT+CLCK= <fac>,<mode>[,<passwd>[,<class>] ]
Response syntax: +CLCK: <status> [ ,<class1> ]
<CR><LF>+CLCK: <status>,<class2>
[ … ] ]
Command
Possible responses
AT+CLCK=”SC”,1,1234
OK
Note: Enable PIN
Note: PIN was right
AT+CLCK?
+CLCK: (”PS”, 0), (”PN,0),(”FD”,0)
Note: Read PIN status
OK
Note: PIN is enables, no SIM lock, no network lock, no
informati_n on Call barring
(
no longer supported
in GSM 07.07)
AT+CLCK=”SC”,0,5555
+CME ERROR: 16
Note: Disable PIN
Note: PIN was wrong
AT+CPIN=1234
OK
Note: Enter PIN
Note: PIN was good
AT+CLCK=?
+CLCK:(”PS”,”SC”,”AO”,”OI”,”OX”,”AI”,”IR”,”AB”,
Note: Request supported
OK
facilities
Note: Supported facilities
AT+CLCK=”PN”,1,12345678 OK
Note: Activate network lock
Network lock activated
AR+CLCK=”AO”,1,1234,2
OK
Note: Activate all outgoing
Note: Call barring is activate
calls barring for data calls
AT+CLCK=”AO”,2
<CR><LF> +CLCK: 1,2
Note: Query BAOC status
OK
Note: BAOC activate for data calls only