4.7 Technical data and operating conditions W121 L,W
Model
W121 L
W121 W
General data
Machine dimensions
-without feet-
H x W x D (mm)
1075 x 860 x 650
1075 x 860 x 650
Adjustable feet
from - till (mm)
150-170
Weight (kg)
109
Cooling
Air
Water
Refrigerant
R 290 (GWP-Wert: 3)
Cooling capacity
1352 W
Production data
Production (kg per day)
about. 126
Storage (kg)
about. 80
Water consumption of ice making
(litres per kg ice)
about. 2,2
Water consumption of cooling
system (litres per kg ice)
-
about. 16
Power supply
Voltage
230 V ~ / 50 Hz
Power consumption
0,96 kW
0,90 kW
Fuse (provided by customer)
> 10 A
Length of connection cable
about. 2,0 m
Water supply
Pressure
2 bis 6 bar
Temperature
5
–25 °C
Water hardness
max. 25 °dH *)
max. 15 °dH *)
Water inlet
device connection -Ø
¾
“ - male thread
hose
–Ø / -length
DN 8 (incl. 2x ¾“ - female thread) / about. 1,5 m
Water outlet
device connection -Ø
20 mm
hose
–Ø / -length
DN 20 / about. 1,4 m
Cooling water outlet
device connection -Ø
-
10 mm
hose
–Ø / -length
-
DN 10 / about. 1,4 m
Environmental conditions
Temperature
10-40°C
10-45°C
Installation position
firm surface, good ventilation
Installation height
at least 10 cm above outlet pipe
The installation surface must be suitable for the weight of the machine.