background image

MAINTENANCE, CLEANING AND STORAGE

Cleaning periodically will prolong the life and proper functioning of the product. The frequency 

of cleaning should be determined by inspection and by severity of the environment. Clean with 

compressed air and/or a stiff brush using plain water or a mild soap and water solution. Do not use 

any corrosive chemicals that could damage the product. Wipe all surfaces with a clean, dry cloth 

and hang to dry, or use compressed air. When not in use, store anchorage connectors in a cool, dry, 

clean environment, out of direct sunlight and free of corrosive or other degrading elements.

*It is essential  for the safety of the end user that if this product is re-sold  outside the original 

country of destination the reseller shall provide instructions for use, maintenence, and for periodic 

examination and repair in the language of the country in which the product is to be used.

 

 

 

Inspection:

Official periodic inspection must be made at least annually. The inspection must be 

performed by a competent or qualified person other than the intended user. If severe 

environmental conditions exist then inspections must be carried out more frequently. All 

inspection results must be logged in the space provided above. (It is recommended that the 

anchor device is marked with the date of the next or last inspection.)

 

 

1. Ensure all labeling is affixed to the unit.

 

2. Inspect anchoring system for signs of damage or wear.

 

3. Ensure the ring is free to swivel and pivot.

 

4. Check for excessive play and wear on the retaining bushing 

 

     (Bushing should not wiggle or rotate.)

 

5. Ensure latches engage and disengage properly.

 

6. Record inspection results in the space provided above.

*If inspection reveals any damage that could affect the strength or operation of the 

device, inadequate maintenance, or an unsafe condition, proper disposal is required. 

The anchorage connector must be rendered unusable and then properly discarded.

MODEL NUMBER:

DATE OF MANUFACTURE:

INSPECTION AND MAINTENANCE LOG

Date

Part Number

Comments

Inspector Name

Содержание A555000

Страница 1: ...MILIAR WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT ALL USERS OF THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THE DEVICE AVOID CONTACT WITH PHYSICAL HAZARDS THERMAL CHEMICAL ELECTRICAL ETC MAKE ONLY COMPATIBLE CONNECTIONS V2 1 B Patent US 8 312 966 US 8 646 575 US 8 973 705 B2 BANTAM BEAMER ADJUSTABLE FROM 3 5 14 inches Model A555000 ...

Страница 2: ...ge connector must be removed from service and destroyed immediately USE LIMITATIONS This anchorage connector has been tested in compliance with the requirements of ANSI ASSE Z359 7 Compliance testing covers only the hardware and does not extend to the anchorage and substrate to which the anchorage connector is attached The anchorage connector must not be used outside its limitations or for any pur...

Страница 3: ...ized beam D ring is centered on the anchorage connector for ease of sliding on beam flanges Particularly in rope access applications bodyweight may disengage the centering feature in some loading conditions This is not a safety concern but it may affect usability Adjustable Directions Notches Latch Handle Notches Latch Handle Adjustable Hook Adjustable Hook PERFORMANCE Minimum Breaking Strength 50...

Страница 4: ... an ANSI Z359 compliant energy absorbing connecting component Energy Absorbing Lanyard or Self Retracting Lifeline and free fall limits of the connecting component must be followed The beam anchor must be attached to the I beam flange facing the user top flange if above bottom flange if below etc ...

Страница 5: ...user shall be equipped with a means of limiting the maximum dynamic forces exerted on the user during the arrest of a fall to a maximum of 8 kN 1800 lbf In the EU these forces must be limited to 6kN 1350 lbf WARNING SWING FALLS MAY OCCUR WHEN THE WORKER IS NOT DIRECTLY UNDER ANCHOR POINT Inspect retaining bushing for wear or damage MINIMUM CLEARANCE 2 feet 6m ...

Страница 6: ...el A555000 Batch XXXX Compliance OSHA 1926 502 OSHA 1910 140 ANSI Z359 18 Type A ANSI Z359 7 19 EN 795 2012 Type B CE 2777 Stainless Steel Aluminum Zinc Plated Steel Bronze Pat US 8 312 966 US 8 646 575 US 8 973 705 B2 MAX 1 888 523 3371 P N 112573 07 REV C 1 21 P N 112573 04 REV E 5 21 2777 WARNING ALL USERS OF THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS FAILURE TO DO SO MAY RESULT I...

Страница 7: ...fficial periodic inspection must be made at least annually The inspection must be performed by a competent or qualified person other than the intended user If severe environmental conditions exist then inspections must be carried out more frequently All inspection results must be logged in the space provided above It is recommended that the anchor device is marked with the date of the next or last...

Страница 8: ...125 1 888 523 3371 www wernerco com 105548 05 REV F 5 21 Notified Body responsible for the EC type examination and ongoing conformity SATRA Technology Europe Ltd Bracetown Business Park Clonee Dublin D15 YN2P Ireland Tel 353 0 1 437 2484 2777 ...

Отзывы: