29
High-Performance Distance Sensor
Notes regarding password functions:
If the password function has been activated, the password must be entered each time supply power to the
Sensor is interrupted.
After pressing a key, the menu is automatically switched to the password entry mode.
The following user interface then appears:
After entering the correct password with the + or – key, the entire menu is enabled and the Sensor is ready for
use.
• The password function is deactivated upon shipment from the factory.
• Passwords can be selected within a range of 0000 to 9999.
Be sure to make a note of the new password before exiting the “change password” function! If the password
is forgotten, it must be overwritten with a master password. The master password can be requested by e-mail
from
8. More Settings and Queries via the RS-232 Interface
(does apply to Y1TA100QXVT80 and Y1TA100MHT88)
The interface makes use of the software handshake procedure. All settings can be configured at a PC and
uploaded to the device. RS-232 interface connections RxD (5) and TxD (4) are linked to minus (pin 3, green),
and can be connected to the corresponding terminals at the communication partner.
Interface configuration:
Adjustable baud rate, 8 data bits, no parity, 1 stop bit
Plug connectors included with the wenglor S232W3 plug adapter:
• 8-pin M12 plug connector for connecting the power supply and the outputs
• 8-pin M12 socket connector for direct Sensor connection
• 9-pin M12 subminiature socket connector for direct connection to the RS-232 interface at the PC, or the uti-
lized controller