23
High-Performance Distance Sensor
7.9. Read-Out
Which data will be read out to the display as measurement results are selected in the
Read-Out menu.
Note: The menu item is only present for the Sensors Y1TA100QXVT80, Y1TA100QXT3 and OY1TA603P0003
if pin function “Analog” is set. The option “Analog” in only present for the sensors Y1TA100MHT88 and
Y1TA100MHV80.
Designation
Function
Key designation
DispMode
Select display characteristics
What will appear at the monitor during display mode operation is selected by pressing the
or the
key:
Distance: The states of the individual outputs appear at the display.
Measured analog
voltage
Distance to the
object
Output configuration/
selected delays
Status of the switch outputs of the
error output or analog output
(if used as analog output: the higher
the analog value, the brighter the
status display)
Analog: The analog output value appears at the display.
Output configuration/selected delays
Analog output value (U/I)
Measured analog
voltage
Distance to the
object
Run
Switch to the read-out view
The device is switched to the display mode by pressing the