26
Functional Overview
Explanation of the individual output values:
Column 2: current distance: read-out of the respective current measuring distance in mm
Column 3: statuses of the digital outputs:
0: not switched
1: switched
# # # #
F A3 A2 A1
Example: 1001
à
error output and output 1 switched.
Column 4: difference between current distance and the selected switching point (for each output)
Example:
wenglor
Output 1: switching threshold at 2800 mm
Output 2: switching threshold at 1500 mm
Output to interface:
Output 1: –000800
Output 2: +000500
Object
2000 mm
Column 5: digital read-out of the current or the voltage value in mV
(depending on the setting in the “Analog” menu)
Column 6: time stamp
Example:
Time Stamp
Measuring Distance
00001024
1805 mm
00001066
1810 mm
99999999
2068 mm
00000000
2068 mm
By outputting the time-stamp, the individual measurement distances can be assigned to a relative time without
taking into consideration the processing speed of the computer.
Time stamp:
D
1
≙
500 µs