High-Performance Distance Sensor
5. Installation Instructions
All applicable electrical and mechanical regulations, standards and safety precautions must be adhered to
when installing and operating the Sensor. The Sensor must be protected against mechanical influences. Install
the device such that its installation position cannot be inadvertently changed. The wenglor mounting system is
recommended for installing the Sensor. In order to obtain best possible results, the device’s optics should be
aligned at a right angle to the direction in which the objects are conveyed.
At brilliant surfaces, mount the Sensor in an angle of 5° to avoid
a direct reflexion beam into the lens.
6. Initial Start-Up
6.1. Initial Start-Up
Connect the Sensor to supply power (18 to 30 V DC). The display view appears.
The Sensor is ready for operation after 2 seconds. The following table provides an overview of typical, addi-
tional deviations during the warm-up phase.
Time (min.)
0
1
2
5
10
15
Deviation (mm)
±10
±7
±6
±2
±1
0
Switch to the configuration menu by pressing any key.
Note:
If no settings are adjusted in the configuration menu for a period of 30 s, the Sensor is automatically returned to
the read-out view. The Sensor accesses the last used menu view when a key is once again activated.
If a setting is adjusted, it becomes active when the configuration menu is exited.
The keys are used for navigation, and for configuring settings.
Important:
Do not use any sharp objects to press the keys when configuring settings, because they might otherwise
be damaged.
Navigation up.
Navigation down.
Acknowledge the selected menu item (arrow points towards the display).
Accept the selected setting, exit the menu (arrow points away from the display).