Project Engineering
98
5.2.5.6 Comparison Blanking Functions
Fix blanking
Fix blanking with
edge tolerance
Floating blanking
Reduced
resolution
Section
Object movement
None
By ± 1 beam within
the safety field
Within the safety
field
Inside and outside
the safety field
Number of objects
Unlimited
Unlimited
Max. 3
Unlimited
Is monitored
Is monitored
Is monitored
Is not monitored
Distance between
the objects
Min. 1 beam
Min. 1 – 3 beams
(dep. on no. object
movements)
Min. 3
According to re-
duced resolution
Min. 1 beam
Min. Object size
1 beam
@14 mm: 14 mm
@30 mm: 30 mm
2
@14 mm: 24 mm
@30 mm: 50 mm
2
@14 mm: 24 mm
@30 mm: 50 mm
None
@14 mm: -
@30 mm: -
Max. Object size
Min. 1 synchroni-
zation beam and
neighboring beam
free
Min. 1 synchroni-
zation beam and
neighbouring beam
free
Both synchroniza-
tion beams free
According to re-
duced resolution
Release of the
safety field
OSSDs OFF (error)
OSSDs OFF (error)
OSSDs OFF (error)
OSSD ON
Release of blanked
beams
OSSDs OFF (error)
OSSDs OFF (error)
OSSDs OFF (error)
OSSD ON
Resolution with
mechanical
construction
According to the
data sheet
With edge area:
According to the
data sheet
Without edge area:
Effective resolution
as with blanking of
1 beam
According to the
data sheet
Not relevant
Resolution without
mechanical con-
struction
According to effec-
tive resolution
According to effec-
tive resolution
According to effec-
tive resolution
According to re-
duced resolution
Parameters
configuration
Teach-in
Teach-in
Teach-in
Teach-in