Parameters Configuration
154
Example 2: Fix blanking is to be parametrized (Teach-in)
Starting point:
• ESPE parameter configuration as per delivery state.
• ESPE is positioned and installed correctly with the correct electrical connection.
• Fix blanking is to be parametrized.
1. Password entry
• PasswordParamEntry: “0000” (current password)
“write”
• ESPE enters parametrization mode (see above for operating display).
• Parameters can be changed and saved.
2. Set the operating mode
• Set Operation Mode to “Fix Blanking”
“write”.
3. Teach-in the blocked area
• Set Param.TeachIn to “Start”
write.
– Bring the desired object into the safety field.
– The number of beams currently blocked is shown in Param.TeachIn.Value (update display if necessary).
– Move the object until the position, size and number of taught-in beams correspond to the final set-up.
– The position of the taught-in beams can also be read off from the process data via parameter set A.
• Set Paramt.Teach In to “Ok”
write
4. Write parameters to ESPE
• Set ParamEnd to “Save and Restart”
write
5. Restart ESPE
• ESPE restarts automatically and the parameter configuration is applied.
• The ESPE then enters normal operation.
9.5.5 Data Storage
• For functional safety reasons, the devices have no data storage function.
• All parameters are saved in the ESPE or can be saved on the microSD card.