Parameters Configuration
134
OSSD
RES
SIG LOW
ERROR
Switch on
• The “override” function enables the OSSDs to be enabled if a
penetration of the safety field is detected and the muting se-
quence is not valid.
• This can be necessary if a valid muting sequence is interrupted
(due to a conveyor belt stop, for example).
– ON: Override activated.
– OFF: Override deactivated.
• For more information on the “override” function, see
OSSD
RES
SIG LOW
ERROR
Switch off
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
NOTE!
• Activating the cross muting function deactivates:
– 2-sensor linear muting,
– 4-sensor linear muting,
– Direction setting.
• Activating belt stop deactivates Full Muting Enable.
• Activating Full Muting Enable also deactivates belt stop.
9.4.8.2 Parametrization 2-Sensor Linear Muting (2L)
• For general information on the 2-sensor linear muting function, see
.
• All settings under the muting function must be carried out in one go. If the 2-sensor linear muting menu
item is called up again, the parameter configurations must be set again for the desired options.
• The following selection options are available for 2-sensor linear muting:
a) Timeout / muting duration
OSSD
RES
SIG LOW
ERROR
300 sec:
• There is a time limit on the maximum duration of an active muting
sequence. There are two values to choose from.
– 300S: Muting duration max. 300 s
– 8H: Muting duration max. 8 h
• For more information on the “muting duration” function, see
OSSD
RES
SIG LOW
ERROR
8 hours
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
b) Belt stop