9.3.3 Menu Structure
The menu is laid out as follows:
Range
HI RANGE
CODE
Coding
9.3.4 Parametrization of the Range and Coding
• The “Menu down” key (
) can be used to switch between the two settings (range/coding).
• The “Apply” key (
) changes the setting within the menu item:
– Range: Switch between low range and high range,
– Coding: Switch between coding ON and coding OFF.
• The current set parameter configuration is indicated by different flashing frequencies:
Display during
parameter configuration
Meaning
Display during oper-
ation
High
Range
Flashing, duty cycle 15 %
LED on
LED off
Low range
HI RAN
Flashing, duty cycle 85 %
LED on
LED off
High range
HI RAN
CODE
Flashing, duty cycle 15 %
LED on
LED off
Coding OFF
CODE
Flashing, duty cycle 85 %
LED on
LED off
Coding ON
CODE
• To apply the settings, both keys ([menu down
] and [apply
]) must be pressed at the same time until
the red “ERROR” LED goes out (approx. 2 s).
• By way of acknowledgment, all LEDs light up at the same time before the final setting is shown according
• If no acknowledgment takes place, the settings are dismissed and the most recent saved setting is applied