7.11. Impulse
Function
Description
Impulse
Adjusting Impulse Duration
A1 Schalt
Impuls
10 ms
+
–
The pulse length defines how long the switching state is held.
A pulse length of 0
to 10000 ms can be set by pressing the “+” key or the “–” key.
After the selected pulse duration has elapsed, the output signal is returned to the
deactivated state.
Object
Impulse
Pulse combined
with ON Delay
Pulse Length
ON Delay
Pulse Length
7.12. Switching Thresholds
The switching thresholds can be set manually via IO-Link or via the RS-232 port, for example with the help of
wenglor’s wTeach configuration software. The software can be downloaded free of charge at: www.wenglor.
com
→