18

EN

Parameter 4 

High Byte Off Delay in ms

Parameter 5 

Low Byte Off Delay in ms

Parameter 6 

High Byte Impulse Duration in ms

Parameter 7 

Low Byte Impulse Duration in ms

Parameter 8 

High Byte of lower Threshold

Parameter 9 

Low Byte of lower Threshold

Parameter 10 

High Byte of upper Threshold

Parameter 11 

Low Byte of upper Threshold

Configuration Page (0x80)

Parameter 1 

Serial number Byte 1

Parameter 2 

Serial number Byte 2

Parameter 3 

Serial number Byte 3

Parameter 4 

Serial number Byte 4

Parameter 5 

DeviceID Byte 1

Parameter 6 

DeviceID Byte 2

Parameter 7 

DeviceID Byte 3

Parameter 8 Revision
Parameter 9 

 

Parameter 10 

 

Parameter 11

Configuration Page (0x81)

Parameter 1 

Filter Settings 

0x00 = not allowed

 

Filter Settings 

0x01 = Filter off

 

Filter Settings 

0x03 = ×2

 

Filter Settings 

0x07 = ×3

 

Filter Settings 

0x0f = ×4

 

Filter Settings 

0x1f = ×5

 

Filter Settings 

0x3f = ×6

 

Filter Settings 

0x7f = ×7

 

Filter Settings 

0xff = ×8

Содержание OPT2041

Страница 1: ...OPT2041 Fiber Optic Cable Sensor Operating Instructions Available as PDF only Status 18 06 2018 www wenglor com EN...

Страница 2: ...tion Instructions 6 4 7 1 Mounting to a DIN rail 6 4 7 2 Side mounting 7 4 7 3 Connecting the plastic fibre optic cable 7 5 Initial Operation 8 5 1 Overview of Functions 8 5 2 Menu Structure 9 6 Adjus...

Страница 3: ...t on the range 2 Safety Precautions This operating instruction is part of the product and must be kept during its entire service life Read this operating instruction carefully before using the product...

Страница 4: ...oltage A Switching Output IO Link T Teach Input Supply Voltage 0 V 4 2 Housing Dimensions 1 Transmitter Diode 2 Receiver Diode 4 3 Declaration of Conformity The EC declaration of conformity can be fou...

Страница 5: ...25 60 C Switching Output Voltage Drop 2 5 V Switching Output Switching Current 100 mA Short Circuit Protection yes Reverse Polarity Protection yes Overload Protection yes Teach Mode NT MT ZT DT FT HT...

Страница 6: ...y 4 7 Installation Instructions All applicable electrical and mechanical regulations standards and safety precautions must be adhered to when installing and operating the Sensor The Sensor must be pro...

Страница 7: ...nting of the Sensor 4 7 3 Connecting the plastic fibre optic cable Please cut the plastic fibre optic cable once before using with the cutting tool Open the mounting slide with a screwdriver see fig 3...

Страница 8: ...functions of the navigation keys vary from menu to menu The functions of the keys appear in the display as follows 5 Navigate up 6 Navigate down 3 Back Move up one level within the menu 7 Run Switch...

Страница 9: ...9 5 2 Menu Structure The Sensor s menu is laid out as follows normal Signal Strength Password Switching Status Indicator Only after Window Teach...

Страница 10: ...e T key Align the spot to the object Briefly press the T key The switching distance to the object is set If necessary readjust the switching distance with the help of the Potentiometer menu item T Dyn...

Страница 11: ...re displayed alternately while the window is being taught in T Background Background Teach In The background is taught in by pressing the T key so that it can be virtual suppressed Align the spot to t...

Страница 12: ...selection is acknowledged by pressing the enter key NO NC Selecting the Output Function The normally open or normally closed output function is selected by press ing the NO or the NC key The respectiv...

Страница 13: ...pressing the Enter key High Sensitivity Highest sensitivity for large ranges Normal Sensitivity Normal sensitivity for standard applications 6 5 Filter The filter function is set in the menu Filter Fu...

Страница 14: ...ar graph is zoomed by pressing the 5 and 6 keys Display elements The elements which will appear at the display can be selected with the 5 and 6 keys and acknowledged by pressing the enter key Displaya...

Страница 15: ...the enter key The password is set to 0 upon shipment from the factory Change Changing the Password The desired new password is selected with the or key Selection is acknowledged and the password is ch...

Страница 16: ...and Process data Addressing via IO Link The Index is set to 1 at all times Thereby the Direct Parameter Page can be reached where then the several Parameters can be set by the Subindexes Subindex 0 re...

Страница 17: ...f Configuration Page Bit 7 Switch to 1 Configuration Page Is Bit 7 in Parameter 0 set to 1 more Configuration Pages can be reached For this purpose the corresponding address of the Configuration Page...

Страница 18: ...Page 0x80 Parameter 1 Serial number Byte 1 Parameter 2 Serial number Byte 2 Parameter 3 Serial number Byte 3 Parameter 4 Serial number Byte 4 Parameter 5 DeviceID Byte 1 Parameter 6 DeviceID Byte 2 P...

Страница 19: ...Parameter 5 Low Byte of Lower Threshold 2 Parameter 6 High Byte of Upper Threshold 2 Parameter 7 Low Byte of Upper Threshold 2 Parameter 8 Parameter 9 Parameter 10 Parameter 11 8 Maintenance Instructi...

Отзывы: