16
EN
• The password function is deactivated upon shipment from the factory.
• The password is set to “0” upon shipment from the factory.
• Passwords can be selected within a range of 0000 to 9999.
It must be assured that the newly selected password is noted before the password is changed. If the
password is forgotten, it must be overwritten with a master password. The master password can be
requested by e-mail from
7. IO-Link Parameter and Process data
Addressing via IO-Link
The Index is set to „1“ at all times. Thereby the Direct Parameter Page can be reached, where then the several
Parameters can be set by the Subindexes.
Subindex „0“
è
read all Parameters
Subindex „1“
è
Parameter 0
read/write
Subindex „2“
è
Parameter 1
read/write
… …
…
Process bytes
Process byte 0
Bit 0
Output status
1 = switched
Bit 1
Contamination
1 = contaminated
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Process byte 1
Bit 0
Signal Strength Bit 0
Bit 1
Signal Strength Bit 1
Bit 2
Signal Strength Bit 2
Bit 3
Signal Strength Bit 3
Bit 4
Signal Strength Bit 4
Bit 5
Signal Strength Bit 5
Bit 6
Signal Strength Bit 6
Bit 7
Signal Strength Bit 7