12
EN
External Teach-In
The last teach-in procedure selected from the menu is used during external teach-in.
For this reason, the desired teach-in procedure must be executed once before external teach-in.
• Set the Sensor to the display mode.
• Apply 10 to 30 V DC to the teach-in input for at least one second.
è
The utilized teach-in procedure appears at the display.
• Disconnect voltage from the teach-in input.
è
The teach-in procedure is executed.
Notes regarding external teach-in:
• The two-point teach-in mode cannot be executed externally.
• In the dynamic teach-in mode, the recording phase continues for as long
as voltage is applied to the teach-in input.
6.3. Output
The device’s output is set up with the help of the output menu.
Function
Description
PNP/Push-Pull
Selecting the Output Type
The PNP or push-pull output type can be selected by pressing the
navigation keys, and the selection is acknowledged by pressing the
enter key.
NO/NC
Selecting the Output Function
The normally open or normally closed output function is selected by press-
ing the NO or the NC key. The respective circuit diagram is displayed.
On-Delay
Adjusting On-Delay
On-delay can be adjusted within a range of 0 to 1000 ms by pressing the
+ or – key.* See figure 4 on page 29.
Off-Delay
Adjusting Off-Delay
Off-delay can be adjusted within a range of 0 to 10000 ms by pressing
the + or – key.* Off-delay is disabled
if a impulse duration has already been selected. See figure 4 on page 29.
Impulse
Adjusting Impulse Duration
Pulse duration defines how long the output
signal remains in the activated state. A impulse
length can be selected within a range
of 0 to 10000 ms by pressing the + or – key.*
After the selected pulse duration has elapsed,
the output signal is returned
to the deactivated state.
(Description applies to NO contacts in scanning
mode or NC contacts in barrier mode.)
Function can be
combined with
ON-Delay
* Press and hold the + or – key in order to scroll quickly through the numbers.