27
Connection Boxes
8. Web-Based Configuration
The Connection Box is equipped with a web-based configuration interface which functions independent of the
operating system. You can configure the Connection Box conveniently at a standard web browser. The web-
server permits monitoring or the setup of a test environment independent of the controller. It’s not required for
normal operation with a controller.
NOTE!
Communication via EoE (Ethernet over EtherCAT) is required in order to be able to access
the integrated webserver’s website. This is only possible via mailbox communication with a
PLC or PC-based control software such as TwinCAT®. All website settings can be entered
when the product is in the Pre-OP mode. Instructions for configuration of the network
parameters can be found in the “Start-Up-EtherCAT-Device” manual (www.wenglor.com
Product World
Product Search (“Enter the product number”)
Download
general
instructions) in the section entitled “Displaying and Working with the Integrated Webserver”.
An active mailbox and active network communication are prerequisites for all further steps.
When operated with a controller, settings which have been changed via the website are
overwritten by the controller or changes are only possible in the pre-op mode.
8.1 Accessing the Administration Interface
Start the web browser. Enter the Connection Box’s IP address to the address line in your browser and press
the enter key. The Connection Box’s IP address is preset to 192.168.100.1. In order to assure that the browser
displays the most current website settings, the respective website must always be automatically reloaded
when a change is made. This setting must be changed in a browser-specific manner which is described here
using the Internet Explorer as an example. Select
Every time I visit the webpage under Tools
Internet
options
General
Settings. Otherwise, changes to the website might not be correctly displayed.