21
Connection Boxes
6.1 LED Display, EtherCAT
The communication status indicator is identified on the Connection Box with STATUS and MS.
STATUS
MS
Designation
Status
Function
Status
Green off
ESM state: initialization
Green blinking
ESM state: PRE-operational
Green lights up once
ESM state: SAFE-operational
Green on
ESM state: operational
Red off
No error
Red on
Application controller failure
Red lights up once
Local error
Red lights up twice
Process data watchdog timeout /
EtherCAT watchdog timeout
Red blinking
Red blinking, invalid configuration
MS (module status)
Off
—
Green
Operate status
Red
Device error
Red blinking
—
The LED display at the M12 sockets indicates the diagnostic status of each respective socket.
0
IO
1.0
IO
0.0
Designation
Status
Function
IO 0.0 / IO 1.0
Yellow
Input
UB to pin 2/4
Output
Switching output to UB pin 2/4
Red
Output
Short-circuit at pin 2/4
L/A
X
Designation
Status
Function
Off
No Ethernet device has been connected to the port.
L/A
Green
An Ethernet device is connected to the port.
Green blinking
An Ethernet device is connected to the port
and is current communicating.
Содержание EtherCAT ZAI02CN0x