20
Sensors for your success
www.wenglor.com
Sensors for your success
www.wenglor.com
EN
Query Sensor Version:
Function
Send Frame to the Sensor
Response Frame from the Sensor
Query Sensor version
/000V49.
/070V8a:bbccqq.
Table 18
a:
Software version
bb:
Sensor group
(luminescence Sensor: OC)
cc:
Sensor type
(A1P05: 01, A1P16: 02; A2P05: 03, A2P16: 04)
qq:
Checksum
Error Messages:
Function
Send Frame to the Sensor
Response Frame from the Sensor
Error frame
Faulty data
/030Xabbqq.
Table 19
If the Sensor receives faulty data, for example an incorrect checksum or an unknown command, it responds
with an error message.
a:
Last valid command
bb:
Last valid command set
qq:
Checksum
10. Maintenance Instructions
• This wenglor Sensor is maintenance-free.
• It is advisable to clean the lens and the display, and to check the plug connections at regular intervals.
• Do not clean with solvents or cleansers which could damage the device.
11. Proper Disposal
wenglor sensoric gmbh does not accept the return of unusable or irreparable products. Respectively valid
national waste disposal regulations apply to product disposal.