Adjusting Off-Delay
• Set the rotary selector switch
Ý
to
Off-Delay
è
Current Off-Delay is displayed (see “Table 1” on page 7)
• Briefly press the plus key
è
Off-delay is increased
• Briefly press the minus key
è
Off-delay is decreased
• Set the rotary selector switch
Ý
to
RUN
Indication of Delay Time Settings
Delay
LED at minus key
LED at plus key
0 ms*
1× blink, pause, 1× blink
Off
1 ms
2× blinks, pause, 2× blinks
Off
2 ms
3× blinks, pause, 3× blinks
Off
5 ms
4× blinks, pause, 4× blinks
Off
10 ms
Off
1× blink, pause, 1× blink
20 ms
Off
2× blinks, pause, 2× blinks
50 ms
Off
3× blinks, pause, 3× blinks
100 ms
Off
4× blinks, pause, 4× blinks
*Default setting
Table 3
8.6. Trigger Function at Pin 5
• Set the rotary selector switch
Ý
to
trigger
• Apply the trigger signal (PNP) to input W (pin 5)
è
Triggering is executed by a positive signal edge
è
The Sensor performs a one-time measurement
è
The outputs are updated once only
• Disconnect the signal from the trigger input
8.7. Returning All Sensor Settings to their Default Values
Sensor settings can be returned to their original factory default values (see “Table 4” on page 7)
• Set the rotary selector switch
Ý
to
RS-232
• Simultaneously press the plus
and minus
keys
è
The LEDs at both keys start blinking
è
The LEDs stop blinking after approximately 5 seconds
• Release both keys
• The Sensor has been returned to its factory default settings