7. Commissioning
7.1. General Device Information
The wenglor
®
AxP luminescence Sensor is available in two different versions as regarding the receiver filter.
The A1Pxx is equipped with a type GG420 receiver filter which allows blue to pass, and the A2Pxx with a type
OG570 receiver filter which allows yellow-green to pass. The AxP16 series has a working distance of 18 mm,
and the AxP05 series has a working distance of 40 mm.
Applications:
Sensor
Receiver
Filtering
Applications
Working Distance
A1P05
420 nm
Blue luminescing surfaces
40 mm
A2P05
570 nm
Yellow-green luminescing surfaces
40 mm
A1P16
420 nm
Blue luminescing surfaces
18 mm
A2P16
570 nm
Yellow-green luminescing surfaces
18 mm
Table 1
7.2. Factory Default Settings
Function
Factory Default Setting
On-delay
off
Off-delay
off
Output stage
PNP
Teach-In mode for external Teach-In
Two-Point
Automatic intensity read-out via RS-232
off
Table 4
8. Function description
8.1. Switching the Output Stage to and from PNP, NPN and Push-Pull
wenglor
®
AxP luminescence Sensors are equipped with programmable output stages. Either PNP, NPN or
Push-Pull can be selected. All outputs are reconfigured when the output stage is switched.
Activating the Output Stage Setup Mode
• Set the rotary selector switch
Ý
to
POTI
• Press and hold the plus
and minus
keys
è
The LEDs at the plus and minus keys lights up
è
The LEDs at the plus and minus keys go out after 1 second
è
The switching status indicator blinks
• Release both keys, namely
and
è
The currently selected output stage operating mode is displayed (see “Table 1”)
è
Depending upon the Sensor‘s current switching status, the switching status indicator blinks rhythmi-
cally after approximately 2 seconds (output switched), or lights up continuously with brief interruptions
(output not switched).