10
AMPERAGE
REQUIRED GAUGE FOR EXTENSION CORDS
25 ft.
50 ft.
100 ft.
150 ft.
15A
14 gauge
12 gauge
Not Recommended
Not Recommended
ELECTRICAL INFORMATION
1. EXAMINE EXTENSION CORD BEFORE USE. Make sure your extension cord is properly wired and in good con-
dition. Always replace a damaged extension cord or have it repaired by a qualified person before using it.
2. DO NOT ABUSE EXTENSION CORD. Do not pull on cord to disconnect from receptacle; always disconnect by
pulling on plug. Disconnect the extension cord from the receptacle before disconnecting the product from the
extension cord. Protect your extension cords from sharp objects, excessive heat and damp/wet areas.
3. USE A SEPARATE ELECTRICAL CIRCUIT FOR YOUR TOOL. This circuit must not be less than a 12-gauge wire
and should be protected with a 15A time-delayed fuse. Before connecting the motor to the power line, make sure
the switch is in the OFF position and the electric current is rated the same as the current stamped on the motor
nameplate. Running at a lower voltage will damage the motor.
When using an extension cord, be sure to use one heavy enough to carry the current your product will draw.
An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. The table below
shows the correct size to be used according to cord length and ampere rating. When in doubt, use a heavier
cord. The smaller the gauge number, the heavier the cord.
GUIDELINES AND RECOMMENDATIONS FOR EXTENSION CORDS
IMPORTANT:
Servicing a double-insulated product requires extreme care and knowledge of the system, and
should be done only by qualified service personnel using identical replacement parts. Always use original factory
replacement parts when servicing.
1. POLARIZED PLUGS. To reduce the risk of electric shock, this equipment has a polarized plug (one blade is wider
than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse
the plug. If it still does not fit, contact a qualified electrician to install a proper outlet. Do not modify the machine
plug or the extension cord in any way.
2. GROUND FAULT CIRCUIT INTERRUPTER PROTECTION (GFCI) should be provided on the circuit or outlet used
for this power tool to reduce the risk of electric shock.
3. SERVICE AND REPAIR. To avoid danger, electrical appliances must only be repaired by qualified service techni-
cian using original replacement parts.
DOUBLE-INSULATED TOOLS
The tool’s electrical system is double insulated where two systems of insulation are provided. This
eliminates the need for the usual three-wire grounded power cord. Double insulated tools do not
need to be grounded, nor should a means for grounding be added to the product. All exposed metal
parts are isolated from the internal metal motor components with protecting insulation.
Содержание TT1015
Страница 38: ...38 NOTES ...
Страница 39: ...39 NOTES ...
Страница 40: ...THANKS FOR REMEMBERING V 2021 12 20 ...