WARNING:
This tool is for indoor use only. Do not expose to rain or use in damp locations.
GROUNDING INSTRUCTIONS
In the event of a malfunction or breakdown, grounding provides the path of
least resistance for an electric current and reduces the risk of electric shock.
This tool is equipped with an electric cord that has an equipment grounding
conductor and a grounding plug. The plug MUST be plugged into a matching
outlet that is properly installed and grounded in accordance with ALL
local codes and ordinances.
Do not modify the plug provided. If it will not fit the outlet, have the proper
outlet installed by a licensed electrician.
IMPROPER CONNECTION of the equipment grounding conductor can result in electric shock. The conduc-
tor with the green insulation (with or without yellow stripes) is the equipment grounding conductor. If repair or
replacement of the electric cord or plug is necessary, do not connect the equipment grounding conductor to a live
terminal.
In all cases, make certain the outlet in question is properly grounded. If you are not sure, have a licensed electri-
cian check the outlet.
GUIDELINES FOR USING EXTENSION CORDS
When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. An
undersized cord will cause a drop in line voltage resulting in loss of power and overheating. The table below shows
the correct size to be used according to cord length and nameplate ampere rating. When in doubt, use a heavier
cord. The smaller the gauge number, the heavier the cord.
Make sure your extension cord is properly wired and in good condition. Always replace a damaged extension
cord or have it repaired by a qualified person before using it. Protect your extension cords from sharp objects,
excessive heat and damp/wet areas.
USE ONLY THREE-WIRE EXTENSION CORDS that have three-pronged plugs and outlets that accept the
tool’s plug as shown in Fig. A. Repair or replace a damaged or worn cord immediately.
Use a separate electrical circuit for your tools. This circuit must not be less than a #12 wire and should be protect-
ed with a 15 A time-delayed fuse. Before connecting the motor to the power line, make sure the switch is in the
OFF position and the electric current is rated the same as the current stamped on the motor nameplate. Running
at a lower voltage will damage the motor.
Grounded
Outlet
3-Prong
Plug
AMPERAGE
REQUIRED GAUGE FOR EXTENSION CORDS
25 ft.
50 ft.
100 ft.
150 ft.
9.5A
18 gauge
16 gauge
14 gauge
12 gauge
ELECTRICAL INFORMATION