![WEMPE 20097 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/wempe/20097/20097_operating-instructions-manual_956203034.webp)
WEMPE digital main clock 20097
Trouble shooting
34
V3.0 01/2011
7 Trouble shooting
Values as the external supply voltage, the accumulator supply voltage and the fuses are
automatically controlled by the main clock.
Should there be an error, the error symbol
"
E
" is flashing in the time display (
Ill.).
In order to have the specific error indicated:
1. Press the
ENTER
key and keep it pressed down.
2. Press the
MENUE
key with the
ENTER
key pressed down, display:
3. Press the
ENTER
key once again.
the specific error message appears:
Should there be several error messages, switch between the messages using the
keys
1
or
2
.
4. Press the MENUE key to return to the time display.
The following error messages could be indicated. Fix the error as described in the column
"remedy":
error message*
meaning
remedy
"Missing Supply"
breakdown of the 24 V DC power supply
restore the power supply
"Internal Fuse Fault"
failure of the main fuse ("MAINS")
replace the main fuse
"External Fuse Fault"
failure of the sec. clock fuse ("SLAVE")
replace the secondary clock fuse.
"Low Batt."
insufficient accumulator voltage
recharge accumulator by
restoring power supply. Should
the accumulator be low again
after a short time, replace it.
*according to the basic configuration.
NOTICE!
Once the power supply is restored, the secondary clocks are automatically adapted to
the current time.
Should you encounter an error that is not shown in the above error table, please contact one
of the following service addresses :
Gerhard D. Wempe KG
Geschäftsbereich Chronometerwerke
Steinstraße 23
20095 Hamburg - Germany
phone:
+49 – 40 – 33 44 8 - 199
fax:
+49 – 40 – 33 44 8 – 676
e-mail:
Internet:
www.chronometerwerke.de
ITRON Elektronik
Willers OHG
Lindenstraße 2
29640 Schneverdingen - Germany
phone:
+49 – 51 99 – 94 - 0
fax :
+49 – 51 99 – 94 - 22
e-mail:
Internet:
www.itron.de
Содержание 20097
Страница 1: ...Operating Instructions WEMPE digital main clock 20097 ...
Страница 40: ...WEMPE digital main clock 20097 Annex 40 V3 0 01 2011 1 3 Circuit boards 1 1 1 Main board Ill 11 Main board ...
Страница 42: ...WEMPE digital main clock 20097 Annex 42 V3 0 01 2011 1 1 3 Oscillator board Ill 13 Oscillator board ...
Страница 59: ...WEMPE digital main clock 20097 Notice V3 0 01 2011 59 Notice ...