WEMPE digital main clock 20097
Operation
26
V3.0 01/2011
Setting of the analogue line:
1. Remove write protection (
1.1.1).
2. Press the key
1
several times until
one of the analogue line setting
menus appears on the display, for
example:
3. Press the
ENTER
key for confirmation. The line number starts flashing.
(The analogue line that needs to be modified, can only be selected once again with the
key
2
if it has not been correctly selected in the main menu).
4. To make the desired settings of the analogue line:
– press the key
3
to set an UT, LT or seconds line.
– press the key
4
to merge two lines to one forwards and backwards running line.
NOTICE!
This setting option is only possible for line 1. After having merged the two lines,
settings for line 2 are no longer indicated in the main menu.
– Press the key
5
to set whether the output impulses are to be transmitted every
minute (second) "
M
" or every half-minute (second) "
H
".
Example for a forwards running
secondary clock line (local time) with
minutes impulse:
5. Press the
ENTER
key to confirm the modification.
To cancel the modifications, press the
MENUE
key twice.
6. Press the
MENUE
key to return to the time display.
1.1.5 Setting of secondary clocks impulse voltage
1. Remove write protection (
1.1.1).
2. Press the key
1
several times until
the message on the right appears on
the display:
(The default setting of the main clock is 12V for the secondary clock impulses.)
3. Press the
ENTER
key for confirmation. The voltage value starts flashing.
4. Press the key
3
to switch between 12V and 24V.
5. Press the
ENTER
key to confirm the modification.
To cancel the modifications, press the
MENUE
key twice.
6. Press the
MENUE
key twice to return to the time display.
Содержание 20097